CNAP Blade Chassis-Staff
(Created page with "hej = CNAP Blade Chassis @ hv.se = There are two chassis in the CNAP network: one Dell, and '''two''' HP == HP BLc 3000 Enclosure == 300px Us...") |
Latest revision as of 07:51, 10 September 2020
hej
Contents |
[edit] CNAP Blade Chassis @ hv.se
There are two chassis in the CNAP network: one Dell, and two HP
[edit] HP BLc 3000 Enclosure
Username: Administrator Password: JUFBSWIX (for blc3001 in b123a, closest to the door)
Username: Administrator Password: 3H0TDQQV (for blc3002 in b123a)
- Setup and Installation Guide vilken kontakt är vilken
- 2007 HP BladeSystem Onboard Administrator User Guide
- 2015 HP BladeSystem Onboard Administrator User Guide
SET MANAGEMENT IP ADDRESS
- Plug in the cable in OA, not uplink !!
- SET IPCONFIG STATIC 1 192.168.16.16 255.255.255.0
Drivers & Firmware
- Serial Number / Product ID: CZC9081KQN / 500041-B21 hp.com/support for BL495c G5 Blade
- BLc3000 hp.com/support for Part Number: 437502-B21
- c3000 HPE BladeSystem c3000 Enclosures SN: CZC8383004
- Unsupported devices: 1166:024a and 103c:3112
- Devices deprecated and unsupported in VMware ESXi 6.0 (2087970)
- PciInfo 1166:024a BCM5785 [HT1000] SATA (Native SATA Mode)
- PciInfo 103c:3112 Probably a HostBasedAdapter (HBA) for storage FibreChannel (FC)
[edit] Blade Management
- Fixing HP ILO2 Java Remote Console fails to start with ClassNotFound remcons.class
- Fixing HP ILO2 Java Remote Console] fails to start with Application Blocked. Click for details security settings...certificate from running
- run the application "Configure Java"
- Under /Security\ press "Edit Site List..." and add the IP-address of youre BladePC (Example: https://192.168.20.181)
- Fix Java:
- Uninstall Mozilla Firefox
- Download win32 Firefox 3.5.19 from ftp.mozilla.org/pub/firefox/releases
- Using Firefox3.5, goto java.com/download/ , run installer (doubleclick), and install java
- Close and restart Mozilla Firefox
- Google "verify java" and test it from the java.com-site
[edit] SWITCH: GbE2c Ethernet Blade Switch
- Christmas Wish: HP Cisco Catalyst 1GbE 3120G Blade Switch 451438-B21 Spare# 451356-001 Ebay or a Catalyst 3020
- Passwsord: admin
- GbE2c Ethernet Blade Switch for HP c-Class Quick Setup Instructions
- 2006: HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Application Guide
- Firmware etc for SN: MY383221E0, www.hpe.com files download
- Dot1q on HP's is called "tagging"
- VLAN tagging on GbE2c
HP Cisco switch: Specs on page 16 -- HP SWITCH CISCO CATALYST 3020 BLADE Cisco MDS 9124e 24-Port Fabric Switch for BLc3000 BLc7000 HP AG642A DS-HP-FC-K9
[edit] Dell Chassi
- DRAC default password
- Service Tag 4TMSR2J
- Drivers and Firmware dell.se/support 4TMSR2J
- Browser: Only Internet Explorer works (IF you enable ssl ver3)
- Java: You must create security exceptions for "https://192.168.20.9" and "https://192.168.20.9" (Instructions)
- Unsupported devices: 1077:3212 and 1077:018a
- PciInfo 1077:3212 ISP2312-based 2Gb Fibre Channel to PCI-X HBA
- 018ARadeon DDR
- ;S 018A PERC 4/im
- P 018A PERC 4/IM
- S 018A PRO/1000 MB Dual Port Server Connection
- 1077 Name: QLogic Corp.
192.168.20.9 <--- Hela "lådan" med alla individuella fysiska servrar. root / calvin Media -> Detach (all) Media -> Attach Server-3 -> Lägg till .iso-filen Console -> Starta om servern -> Boot menu -> Kör .iso Efter vi gjort inställningar kan vi nu SSHa in
[edit] IT's DELL Chassi
- ITs Address: blc04.server.hv.se
- Chassi: CMC-HBJP85J | M1000e | Service Tag: HBJP85J
- dell.com/support drivrutiner mm för chassi HBJP85J
- Java KVM: Use ENG keyboard in windows to type "_" in password !!!
- Blades: Model PowerEdgeM710HD | Service Tag 83XN85J
- dell.com/support drivrutiner mm för CPU-blade 83XN85J
- CPU Information 2 x Intel(R) Xeon(R) CPU E5649 @ 2.53GHz
- Total System Memory 192.0 GB
- CNAP Management address: 192.168.17.xx
- ITs address:
- [ssh://blc04-swc1.server.hv.se ssh blc04-swc1.server.hv.se] a.k.a. 192.168.17.47
- respektive [ssh://blc04-swc2.server.hv.se ssh blc04-swc2.server.hv.se]
- 10GBE Switch a.k.a. I/O Module (IOM)
- Model M8024-k 10GbE SW
- Service Tag 4CJP85J
Fixa så att nya portar finns med i 'show vlan'
interf te1/0/9 switchport mode access sw acc vlan 36 sw acc vlan 37 sw acc vlan 10 sw acc vlan 11 sw acc vlan 12 sw acc vlan 13 sw acc vlan 10 sw acc vlan 30 sw acc vlan 31 switchport mode trunk switchport general allowed vlan add 2-41,43-1017 tagged
Låt länkar till ESXi slockan om Te1/0/17 slocknar
link-dependency group 1 add Te1/0/1-16 depends-on Te1/0/17 exit show link-dependency GroupId Member Ports Ports Depended On Link Action Group State ------- ---------------------------------- -------------------- ----------- ----------- 1 Te1/0/1-16 Te1/0/17 Link Down Up
[edit] IP Addresses
alfa.cnap.hv.se[/var/named]# grep 3000 db.cnap.hv.se blc3000.cnap.hv.se. 3600 IN A 192.168.20.8 hp-left.cnap.hv.se 3600 IN A 192.168.17.38 hp-right.cnap.hv.se 3600 IN A 192.168.17.39 Blade-left.cnap.hv.se. 3600 IN A 192.168.17.26 Blade-right.cnap.hv.se. 3600 IN A 192.168.17.25
[edit] HP Switch Configuration
>> Information# /info/port
Port Tag RMON PVID NAME VLAN(s) ---- --- ---- ----- -------------- ------------------------------- 1 y d 1* Downlink1 1 11 12 16 20 2 y d 1* Downlink2 1 11 12 16 20 3 y d 1* Downlink3 1 11 12 16 20 4 y d 1* Downlink4 1 11 12 16 20 5 y d 1* Downlink5 1 11 12 16 20 6 y d 1* Downlink6 1 11 12 16 20 7 y d 1* Downlink7 1 11 12 16 20 8 y d 1* Downlink8 1 11 12 16 20 9 y d 2 Downlink9 2 10 n d 2 Downlink10 2 11 n d 2 Downlink11 2 12 n d 2 Downlink12 2 13 n d 2 Downlink13 2 14 n d 2 Downlink14 2 15 n d 2 Downlink15 2 16 n d 2 Downlink16 2 17 n d 1* Xconnect1 1 18 n d 1* Xconnect2 1 19 n d 4095 Mgmt 4095 20 n d 1* Uplink1 1 21 n d 2 Uplink2 2 22 n d 2 Uplink3 2 23 n d 1* Uplink4 1 24 y d 1* Uplink5 1 11 12 16 17 20 42 * = PVID is tagged.
>> Information# /info/l2/vlan
VLAN Name Status Ports ---- -------------------------------- ------ ------------------------- 1 Default VLAN ena 1-14 17 18 20 23 24 Reminder: Port 17 needs to be enabled. Reminder: Port 18 needs to be enabled. 2 STORAGE ena 15 16 21 22 10 VLAN 10 ena 9 11 HP-VildaVastern ena 1-8 24 12 HP-StudentLab ena 1-8 24 16 HP-NATciscoLabPC ena 1-8 24 17 RA Mgmnt VLAN ena 24 20 VLAN 20 ena 1-8 24 42 Native Blackhole VLAN ena 24 4095 Mgmt VLAN ena 19
[edit] CNAP uplink trunk on port 24
- Use . (single period) to print menu
- Use .. to move up one level
switchport mode trunk
/cfg/port Enter port (1-24): 24 >> Port 5# tag Current VLAN tag support: disabled Enter new VLAN tag support [d/e]: e
create vlan
/cfg/l2/vlan Enter VLAN number: (1-4095) 17 ena Current status: disabled New status: enabled /cfg/l2/vlan Enter VLAN number: (1-4095) 17 name "RA Management VLAN"
allowed-vlans
/cfg/l2/vlan 17 add 24 /cfg/l2/vlan 20 add 24 /cfg/l2/vlan 24 add 24
Before you finish remember to apply and save the changes. You apply them to make them active, and you save them so they are persistent between reboots of the switch.
apply save
[edit] iSCSI Storage LAN -- using VLAN 2
- Use . (single period) to print menu
- Use .. to move up one level
Create, Name & Enable VLAN 2
>> VLAN 2# /cfg/l2/vlan/name Enter VLAN number: (1-4095) 2 Current VLAN name: Pending new VLAN name: VLAN 2 Enter new VLAN name: STORAGE >> VLAN 2# /cfg/l2/vlan/ Enter VLAN number: (1-4095) 2 ------------------------------------------------------------ [VLAN 2 Menu] name - Set VLAN name stg - Assign VLAN to a Spanning Tree Group add - Add port to VLAN rem - Remove port from VLAN def - Define VLAN as list of ports ena - Enable VLAN dis - Disable VLAN del - Delete VLAN cur - Display current VLAN configuration >> VLAN 2# ena Current status: disabled New status: enabled >> VLAN 2# apply >> VLAN 2# /info/l2/vlan/dump
ADD PORTS TO VLAN
>> VLAN 1# /cfg/l2/vlan/ Enter VLAN number: (1-4095) 2 ------------------------------------------------------------ [VLAN 2 Menu] name - Set VLAN name stg - Assign VLAN to a Spanning Tree Group add - Add port to VLAN rem - Remove port from VLAN def - Define VLAN as list of ports ena - Enable VLAN dis - Disable VLAN del - Delete VLAN cur - Display current VLAN configuration >> VLAN 2# add Current VLAN 2: empty Enter port to be added: 21 Current ports for VLAN 2: empty Pending new ports for VLAN 2: 21 >> VLAN 2# add Current VLAN 2: empty Current ports for VLAN 2: empty Pending new ports for VLAN 2: 21 Enter port to be added: 22 Current ports for VLAN 2: empty Pending new ports for VLAN 2: 21 22 >> VLAN 2# add Current VLAN 2: empty Current ports for VLAN 2: empty Pending new ports for VLAN 2: 21 22 Enter port to be added: 15 Current ports for VLAN 2: empty Pending new ports for VLAN 2: 15 21 22 >> VLAN 2# add Current VLAN 2: empty Current ports for VLAN 2: empty Pending new ports for VLAN 2: 15 21 22 Enter port to be added: 16 Current ports for VLAN 2: empty Pending new ports for VLAN 2: 15 16 21 22 >> VLAN 2# /info/l2/vlan/dump
Configure default VLAN on ports
>> Port 1# /cfg/port/pvid Enter port (1-24): 15 Current port VLAN ID: 1 Enter new port VLAN ID [1-4094]: 2 >> Port 15# /cfg/port/pvid Enter port (1-24): 16 Current port VLAN ID: 1 Enter new port VLAN ID [1-4094]: 2 >> Port 16# /cfg/port/pvid Enter port (1-24): 21 Current port VLAN ID: 1 Enter new port VLAN ID [1-4094]: 2 >> Port 21# /cfg/port/pvid Enter port (1-24): 22 Current port VLAN ID: 1 Enter new port VLAN ID [1-4094]: 2 >> Port 22#
>> Port 15# tagpvid Current tag pvid support: enabled Enter new tag pvid support [d/e]: d Port 16 changed to pvid untagged. >> Port 16# tagpvid Current tag pvid support: enabled Enter new tag pvid support [d/e]: d Port 16 changed to pvid untagged. >> Port 16# cur Current port 16 configuration: enabled, PVID 2 name Downlink16 The DLF rate control currently turned off The Multicast rate control currently turned off The Broadcast rate control currently turned off 802.1p priority: 0 ACL Port config is empty >> Port 16#
Before you finish remember to apply and save the changes. You apply them to make them active, and you save them so they are persistent between reboots of the switch.
apply save
[edit] Remote Management: Telnet Connectivity
Configuring an IP Interface
Källa: BLADE OS Application Guide HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Version 5.1 Advanced Functionality Software
1.Configure an IP interface for the Telnet connection, using the sample IP address of 205.21.17.3. 2.The pending subnet mask address and broadcast address are automatically calculated. 3.If necessary, configure up to two default gateways. 4.Configuring the default gateways allows the switch to send outbound traffic to the routers. 5.Apply, verify, and save the configuration. #/cfg/l3/if 256 (Select IP interface 256, used by web-GUI for administration) IP Interface 256#addr 192.168.17.39(Assign IP address for the interface) Current IP address: 0.0.0.0 New pending IP address: 205.21.17.39 IP Interface 256# mask 255.255.255.0 Pending new subnet mask: 255.255.255.0 IP Interface 1#ena (Enable IP interface 1) IP Interface 5#/cfg/l3/gw 1 (Select primary default gateway) Default gateway 1#addr 192.168.17.1 (Assign IP address for primary router) Default gateway 1#ena (Enable primary default gateway) Default gateway 1#../gw 2 (Select secondary default gateway) Default gateway 2#addr 0.0.0.0 (Assign address for secondary router) Default gateway 2#disable (DISEnable secondary default gateway) Default gateway 2#apply (Apply the configuration) Default gateway 2#save (Save the configuration) #/info/l3/ip #/cfg/dump (Verify the configuration)
Select VLAN for Management Port
Källa: Deploying the HP GbE2c Ethernet Blade Switch for HP c-Class BladeSystem into a Cisco-based Network HOWTO
/cfg/l2/vlan 17 <-- DOES NOT WORK add 19 <-- port 19 will NOT move !! /cfg/l3/if <number> /vlan <vlan#> /ena/apply
>> Layer 3# dump IP information: Interface information: 1: 192.168.20.191 255.255.255.0 192.168.20.255, vlan 20, up <-- WRONG ?!? 17: 192.168.17.48 255.255.255.0 192.168.17.255, vlan 17, up 256: 10.10.10.10 255.255.255.0 10.10.10.255, vlan 4095, up
[edit] LLDP = IEEE 802.1ab protocol (CDP-like functionality)
Link Layer Discovery Protocol. An IEEE 802.1ab protocol that provides CDP-like functionality
Källa: BLADE OS Application Guide HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Version 5.1 Advanced Functionality Software Globally enable LLDP
/cfg/l2/lldp/on
Port Level: Transmit and Receive Control
/cfg/l2/lldp/port >> LLDP Port# admstat tx_rx (Transmit and receive LLDP) >> LLDP Port# admstat tx_only (Only transmit LLDP) >> LLDP Port# admstat rx_only (Only receive LLDP) >> LLDP Port# admstat disabled (Do not participate in LLDP) >> # /cfg/l2/lldp/cur (View LLDP status of all ports) or >> # /cfg/l2/lldp/port <n> /cur (View status of the selected port)
Cisco IOS
conf t lldp run interface range gig 0/1 - 24 lldp
[edit] >> Layer 2# /info/l2/vlan/dump
VLAN Name Status Ports ---- -------------------------------- ------ ------------------------- 1 Default VLAN ena 1-18 20-24 Reminder: Port 17 needs to be enabled. Reminder: Port 18 needs to be enabled. 10 VLAN 10 ena 9 16 VLAN 16 dis 1-8 Reminder: VLAN 16 needs to be enabled. 17 RA Mgmnt VLAN ena 24 20 VLAN 20 ena 1-8 24 42 Native Blackhole VLAN ena 24 4095 Mgmt VLAN ena 19 ------------------------------------------------------------------ upfast disabled, update 40 Pvst+ compatibility mode enabled ------------------------------------------------------------------ Spanning Tree Group 1: On (STP/PVST+) VLANs: 1 10 16 17 20 42 Reminder: VLAN 16 needs to be enabled. Current Root: Path-Cost Port Hello MaxAge FwdDel 6001 00:21:1b:ec:da:00 8 24 2 20 15 Parameters: Priority Hello MaxAge FwdDel Aging 65534 2 20 15 300 Port Priority Cost FastFwd State Designated Bridge Des Port ---- -------- ---- -------- ---------- --------------------- -------- 1 0 0 n FORWARDING * 2 0 0 n FORWARDING * 3 0 0 n FORWARDING * 4 0 0 n FORWARDING * 5 0 0 n FORWARDING * 6 0 0 n FORWARDING * 7 0 0 n FORWARDING * 8 0 0 n FORWARDING * 9 0 0 n FORWARDING * 10 0 0 n FORWARDING * 11 0 0 n FORWARDING * 12 0 0 n FORWARDING * 13 0 0 n FORWARDING * 14 0 0 n FORWARDING * 15 0 0 n FORWARDING * 16 0 0 n FORWARDING * 17 128 0! n DISABLED 18 128 0! n DISABLED 20 128 0! n DISABLED 21 128 0! n DISABLED 22 128 0! n DISABLED 23 128 0! n DISABLED 24 128 4! n FORWARDING 8001-d4:d7:48:17:45:00 8019 * = STP turned off for this port. ! = Automatic path cost. ------------------------------------------------------------------ Spanning Tree Group 128: Off (STP/PVST+), FDB aging timer 300 VLANs: 4095 Port Priority Cost FastFwd State Designated Bridge Des Port ---- -------- ---- -------- ---------- --------------------- -------- 19 0 0 n FORWARDING * * = STP turned off for this port. ------------------------------------------------------------------ MSTP is not on. VLAN Name Status Ports ---- -------------------------------- ------ ------------------------- 1 Default VLAN ena 1-18 20-24 Reminder: Port 17 needs to be enabled. Reminder: Port 18 needs to be enabled. 10 VLAN 10 ena 9 16 VLAN 16 dis 1-8 Reminder: VLAN 16 needs to be enabled. 17 RA Mgmnt VLAN ena 24 20 VLAN 20 ena 1-8 24 42 Native Blackhole VLAN ena 24 4095 Mgmt VLAN ena 19 Trunk group 1: Enabled Protocol - Static Port State: 17: STG 1 DOWN Reminder: Port 17 needs to be enabled. 18: STG 1 DOWN Reminder: Port 18 needs to be enabled. Forwarding database information: Mac address Aging Time: 300 MAC address VLAN Port Trnk State Permanent ----------------- ---- ---- ---- ----- 00:0c:29:5c:13:38 20 5 FWD 00:0c:29:5d:4d:c1 20 2 FWD 00:0c:29:75:a1:0d 20 1 FWD 00:0c:29:eb:93:26 20 3 FWD 00:15:c5:fd:6d:57 1 24 FWD 00:15:c5:fd:dc:6a 1 24 FWD 00:1b:d4:a8:9c:1a 1 24 FWD 00:1f:29:e7:24:0c 4095 19 FWD 00:1f:29:e7:24:0d 20 24 FWD 00:21:1b:ec:da:47 17 24 FWD 00:21:1b:ec:da:4a 20 24 FWD 00:21:1b:ec:da:4a 4095 19 FWD 00:21:5a:f5:cf:28 20 3 FWD 00:21:5a:f5:dc:ac 20 1 FWD 00:21:5a:f5:e0:08 20 2 FWD 00:22:00:1a:36:01 20 24 FWD 00:50:56:89:6f:4a 20 1 FWD 00:50:56:89:6f:4a 4095 19 FWD 00:50:56:91:bb:89 20 24 FWD 00:50:56:91:bb:89 4095 19 FWD 00:50:56:93:1c:09 20 24 FWD 00:50:56:93:1c:09 4095 19 FWD 00:50:56:93:8c:f2 20 24 FWD 00:50:56:93:8c:f2 4095 19 FWD 00:50:56:bc:7b:57 20 4 FWD 00:50:56:bc:a7:23 20 4 FWD 00:50:56:bc:a7:23 4095 19 FWD 00:50:56:bd:e2:31 20 3 FWD 00:50:56:bd:e2:31 4095 19 FWD d4:d7:48:17:45:19 1 24 FWD d4:d7:48:17:45:19 10 24 FWD d4:d7:48:17:45:19 17 24 FWD d4:d7:48:17:45:19 20 24 FWD d4:d7:48:17:45:1a 4095 19 FWD 802.1x Operational Info: ------------------------------------------------------------------ System capability : Authenticator System status : disabled Protocol version : 1 Authenticator Backend Port Auth Mode Auth Status PAE State Auth State ---- ------------ ------------ -------------- ---------- 1 force-auth unauthorized initialize initialize 2 force-auth unauthorized initialize initialize 3 force-auth unauthorized initialize initialize 4 force-auth unauthorized initialize initialize 5 force-auth unauthorized initialize initialize 6 force-auth unauthorized initialize initialize 7 force-auth unauthorized initialize initialize 8 force-auth unauthorized initialize initialize 9 force-auth unauthorized initialize initialize 10 force-auth unauthorized initialize initialize 11 force-auth unauthorized initialize initialize 12 force-auth unauthorized initialize initialize 13 force-auth unauthorized initialize initialize 14 force-auth unauthorized initialize initialize 15 force-auth unauthorized initialize initialize 16 force-auth unauthorized initialize initialize *17 force-auth unauthorized initialize initialize *18 force-auth unauthorized initialize initialize *20 force-auth unauthorized initialize initialize *21 force-auth unauthorized initialize initialize *22 force-auth unauthorized initialize initialize *23 force-auth unauthorized initialize initialize 24 force-auth unauthorized initialize initialize ------------------------------------------------------------------ * - Port down or disabled STP uplink fast mode : disabled >> Layer 2#
[edit] iLO: SHOW ALL from command-line
Original configuration:
----------------------------------------------------------------------------- WARNING: This is a private system. Do not attempt to login unless you are an authorized user. Any authorized or unauthorized access and use may be moni- tored and can result in criminal or civil prosecution under applicable law. ----------------------------------------------------------------------------- Firmware Version: 3.71 Built: 12/07/2012 @ 13:26 OA Bay Number: 1 OA Role: Active OA-BYGGBLADE login: HP Onboard Administrator booting... HP Onboard Administrator * ********** **** *************** ****** ****************** ******** ********************* ******** *********************** ******** ************************ ******** ***** **** ********* **** **** **** ***** ******** **** ***** ***** ***** ******* **** ***** **** ****** ******* **** ***** **** ******* ****** **** **** **** ******* ***** **** ***** ***** ******** *** **** ***** ******** ***************** **************** *************** *************** ************** *************** *********** ************* ******** ************ *** ********* [16] Subsystems init: [ 9] Enabling protocols: telnet ssh http ntp Onboard Administrator's static IP address is: 10.0.209.19 ----------------------------------------------------------------------------- WARNING: This is a private system. Do not attempt to login unless you are an authorized user. Any authorized or unauthorized access and use may be moni- tored and can result in criminal or civil prosecution under applicable law. ----------------------------------------------------------------------------- Firmware Version: 3.71 Built: 12/07/2012 @ 13:26 OA Bay Number: 1 OA Role: Active OA-BYGGBLADE login: ----------------------------------------------------------------------------- WARNING: This is a private system. Do not attempt to login unless you are an authorized user. Any authorized or unauthorized access and use may be moni- tored and can result in criminal or civil prosecution under applicable law. ----------------------------------------------------------------------------- Firmware Version: 3.71 Built: 12/07/2012 @ 13:26 OA Bay Number: 1 OA Role: Active OA-BYGGBLADE login: ----------------------------------------------------------------------------- WARNING: This is a private system. Do not attempt to login unless you are an authorized user. Any authorized or unauthorized access and use may be moni- tored and can result in criminal or civil prosecution under applicable law. ----------------------------------------------------------------------------- Firmware Version: 3.71 Built: 12/07/2012 @ 13:26 OA Bay Number: 1 OA Role: Active OA-BYGGBLADE login: HP Onboard Administrator booting... Lost Password or Flash Recovery requested Press L for Lost Password Recovery Press F for Flash Recovery Press any other key to reset Booting in Lost Password Mode... HP Onboard Administrator * ********** **** *************** ****** ****************** ******** ********************* ******** *********************** ******** ************************ ******** ***** **** ********* **** **** **** ***** ******** **** ***** ***** ***** ******* **** ***** **** ****** ******* **** ***** **** ******* ****** **** **** **** ******* ***** **** ***** ***** ******** *** **** ***** ******** ***************** **************** *************** *************** ************** *************** *********** ************* ******** ************ *** ********* Subsystems init: [16] dministrator password reset to: JUFBSWIX [ 9] Enabling protocols: telnet ssh http ntp Onboard Administrator's static IP address is: 10.0.209.19 ----------------------------------------------------------------------------- WARNING: This is a private system. Do not attempt to login unless you are an authorized user. Any authorized or unauthorized access and use may be moni- tored and can result in criminal or civil prosecution under applicable law. ----------------------------------------------------------------------------- Firmware Version: 3.71 Built: 12/07/2012 @ 13:26 OA Bay Number: 1 OA Role: Active OA-BYGGBLADE login: root Password: Login incorrect OA-BYGGBLADE login: administrator Password: Login incorrect OA-BYGGBLADE login: admin Password: Login incorrect ----------------------------------------------------------------------------- WARNING: This is a private system. Do not attempt to login unless you are an authorized user. Any authorized or unauthorized access and use may be moni- tored and can result in criminal or civil prosecution under applicable law. ----------------------------------------------------------------------------- Firmware Version: 3.71 Built: 12/07/2012 @ 13:26 OA Bay Number: 1 OA Role: Active OA-BYGGBLADE login: Administrator Password: HP BladeSystem Onboard Administrator (C) Copyright 2006-2012 Hewlett-Packard Development Company, L.P. Type 'HELP' to display a list of valid commands. Type 'HELP <command>' to display detailed information about a specific command. Type 'HELP HELP' to display more detailed information about the help system. OA-BYGGBLADE> help ADD ASSIGN CLEAR CONNECT DISABLE DISCOVER DOWNLOAD EDIT ENABLE EXIT FORCE GENERATE HELP HISTORY HPONCFG LOGOUT PING POWEROFF POWERON QUIT REBOOT REMOVE RESTART SAVE SEND SET SHOW SLEEP TEST UNASSIGN UPDATE UPLOAD OA-BYGGBLADE> help show SHOW { ALL | CA | CONFIG | DATE | DEVICE | DISPLAY EVENT(S) | EBIPA | ENCLOSURE | ENCRYPTION | FIPS MODE | FIRMWARE MANAGEMENT | FRU | HEALTH | HPSIM INFO | INTERCONNECT | LDAP | LOGIN_BANNER | NETWORK | OA | PASSWORD SETTINGS | POWER | RACK | REMOTE_SUPPORT | SERVER | SESSION TIMEOUT | SNMP | SOLUTIONSID | SSHFINGERPRINT | SSHKEY | SYSLOG | TOPOLOGY | TWOFACTOR | UPDATE | URB | USBKEY | USER | VCMODE | VLAN } OA-BYGGBLADE> SET IPCONFIG STATIC 1 192.168.16.16 255.255.255.0 Static IP settings successfully updated. These setting changes will take effect immediately. OA-BYGGBLADE> show ip Invalid Arguments SHOW { ALL | CA | CONFIG | DATE | DEVICE | DISPLAY EVENT(S) | EBIPA | ENCLOSURE | ENCRYPTION | FIPS MODE | FIRMWARE MANAGEMENT | FRU | HEALTH | HPSIM INFO | INTERCONNECT | LDAP | LOGIN_BANNER | NETWORK | OA | PASSWORD SETTINGS | POWER | RACK | REMOTE_SUPPORT | SERVER | SESSION TIMEOUT | SNMP | SOLUTIONSID | SSHFINGERPRINT | SSHKEY | SYSLOG | TOPOLOGY | TWOFACTOR | UPDATE | URB | USBKEY | USER | VCMODE | VLAN } OA-BYGGBLADE> show ipconfig Invalid Arguments SHOW { ALL | CA | CONFIG | DATE | DEVICE | DISPLAY EVENT(S) | EBIPA | ENCLOSURE | ENCRYPTION | FIPS MODE | FIRMWARE MANAGEMENT | FRU | HEALTH | HPSIM INFO | INTERCONNECT | LDAP | LOGIN_BANNER | NETWORK | OA | PASSWORD SETTINGS | POWER | RACK | REMOTE_SUPPORT | SERVER | SESSION TIMEOUT | SNMP | SOLUTIONSID | SSHFINGERPRINT | SSHKEY | SYSLOG | TOPOLOGY | TWOFACTOR | UPDATE | URB | USBKEY | USER | VCMODE | VLAN } OA-BYGGBLADE> show ipconfig 1 Invalid Arguments SHOW { ALL | CA | CONFIG | DATE | DEVICE | DISPLAY EVENT(S) | EBIPA | ENCLOSURE | ENCRYPTION | FIPS MODE | FIRMWARE MANAGEMENT | FRU | HEALTH | HPSIM INFO | INTERCONNECT | LDAP | LOGIN_BANNER | NETWORK | OA | PASSWORD SETTINGS | POWER | RACK | REMOTE_SUPPORT | SERVER | SESSION TIMEOUT | SNMP | SOLUTIONSID | SSHFINGERPRINT | SSHKEY | SYSLOG | TOPOLOGY | TWOFACTOR | UPDATE | URB | USBKEY | USER | VCMODE | VLAN } OA-BYGGBLADE> help show SHOW { ALL | CA | CONFIG | DATE | DEVICE | DISPLAY EVENT(S) | EBIPA | ENCLOSURE | ENCRYPTION | FIPS MODE | FIRMWARE MANAGEMENT | FRU | HEALTH | HPSIM INFO | INTERCONNECT | LDAP | LOGIN_BANNER | NETWORK | OA | PASSWORD SETTINGS | POWER | RACK | REMOTE_SUPPORT | SERVER | SESSION TIMEOUT | SNMP | SOLUTIONSID | SSHFINGERPRINT | SSHKEY | SYSLOG | TOPOLOGY | TWOFACTOR | UPDATE | URB | USBKEY | USER | VCMODE | VLAN } OA-BYGGBLADE> show all >SHOW HEALTH Enclosure Health: Enclosure: Degraded Power Subsystem: Degraded Cooling Subsystem: OK Blade Health: Bay Status Problem Corrective Action --- -------------------- ---------------------- -------------------------------- 1 Absent 2 Error Missing Device This device needs a partner blade in order to function properly. The partner device must be installed adjacent to this device and within the same partition indicated by the dividers. 3 Absent 4 Absent 5 Absent 6 Absent 7 Absent 8 Absent Interconnect Health: Bay Status Problem Corrective Action --- -------------------- ---------------------- -------------------------------- 1 OK 2 OK 3 Absent 4 Absent Power Supply Health: Bay Status Problem Corrective Action --- -------------------- ---------------------- -------------------------------- 1 Error Power Cord The pwr cord of power supplies is unplugged or loose. Please plug in all pwr cords to the available power supplies. 2 OK 3 Absent 4 Error Power Cord The pwr cord of power supplies is unplugged or loose. Please plug in all pwr cords to the available power supplies. 5 OK 6 Absent Fan Health: Bay Status Problem Corrective Action --- -------------------- ---------------------- -------------------------------- 1 OK 2 OK 3 OK 4 OK 5 OK 6 OK Onboard Administrator Health: Bay Status Problem Corrective Action --- -------------------- ---------------------- -------------------------------- 1 OK >SHOW CONFIG #Script Generated by Administrator #Generated on: Thu Oct 15 09:16:29 2015 #Set Enclosure Time SET TIMEZONE Etc/GMT+1 #SET DATE MMDDhhmm{{CC}YY} #Set Enclosure Information SET ENCLOSURE ASSET TAG "" SET ENCLOSURE NAME "CZC8383004" SET RACK NAME "ByggBlade" SET POWER MODE REDUNDANT SET POWER SAVINGS ON #Power limit must be within the range of 950-8750 SET POWER LIMIT OFF #Enclosure Dynamic Power Cap must be within the range of 820-1459 #Derated Circuit Capacity must be within the range of 820-1459 #Rated Circuit Capacity must be within the range of 820-1459 SET ENCLOSURE POWER_CAP OFF SET ENCLOSURE POWER_CAP_BAYS_TO_EXCLUDE None #Set PowerDelay Information SET INTERCONNECT POWERDELAY 1 0 SET INTERCONNECT POWERDELAY 2 0 SET INTERCONNECT POWERDELAY 3 0 SET INTERCONNECT POWERDELAY 4 0 SET SERVER POWERDELAY 1 0 SET SERVER POWERDELAY 2 0 SET SERVER POWERDELAY 3 0 SET SERVER POWERDELAY 4 0 SET SERVER POWERDELAY 5 0 SET SERVER POWERDELAY 6 0 SET SERVER POWERDELAY 7 0 SET SERVER POWERDELAY 8 0 SET SERVER POWERDELAY 1A 0 SET SERVER POWERDELAY 2A 0 SET SERVER POWERDELAY 3A 0 SET SERVER POWERDELAY 4A 0 SET SERVER POWERDELAY 5A 0 SET SERVER POWERDELAY 6A 0 SET SERVER POWERDELAY 7A 0 SET SERVER POWERDELAY 8A 0 SET SERVER POWERDELAY 1B 0 SET SERVER POWERDELAY 2B 0 SET SERVER POWERDELAY 3B 0 SET SERVER POWERDELAY 4B 0 SET SERVER POWERDELAY 5B 0 SET SERVER POWERDELAY 6B 0 SET SERVER POWERDELAY 7B 0 SET SERVER POWERDELAY 8B 0 #Configure Protocols ENABLE WEB ENABLE SECURESH ENABLE TELNET ENABLE XMLREPLY DISABLE GUI_LOGIN_DETAIL ENABLE ACTIVE_HEALTH_SYSTEM #Configure Alertmail SET ALERTMAIL SMTPSERVER 0.0.0.0 DISABLE ALERTMAIL #Configure Trusted Hosts #REMOVE TRUSTED HOST ALL DISABLE TRUSTED HOST #Configure NTP SET NTP PRIMARY 192.36.144.22 SET NTP SECONDARY 192.36.143.151 SET NTP POLL 720 ENABLE NTP #Set SNMP Information SET SNMP CONTACT "" SET SNMP LOCATION "" SET SNMP COMMUNITY READ "public" SET SNMP COMMUNITY WRITE "" DISABLE SNMP #Set Remote Syslog Information SET REMOTE SYSLOG SERVER "" SET REMOTE SYSLOG PORT 514 DISABLE SYSLOG REMOTE #Set Enclosure Bay IP Addressing (EBIPA) Information for Device Bays #NOTE: SET EBIPA commands are only valid for OA v3.00 and later SET EBIPA SERVER 10.0.209.83 255.255.255.0 1 SET EBIPA SERVER GATEWAY 10.0.209.1 1 SET EBIPA SERVER DOMAIN "byggtjanst.local" 1 ADD EBIPA SERVER DNS 10.0.209.30 1 ADD EBIPA SERVER DNS 10.0.209.31 1 ENABLE EBIPA SERVER 1 SET EBIPA SERVER NONE NONE 1A SET EBIPA SERVER GATEWAY 10.0.209.1 1A SET EBIPA SERVER DOMAIN "byggtjanst.local" 1A ADD EBIPA SERVER DNS 10.0.209.30 1A ADD EBIPA SERVER DNS 10.0.209.31 1A DISABLE EBIPA SERVER 1A SET EBIPA SERVER NONE NONE 1B SET EBIPA SERVER GATEWAY 10.0.209.1 1B SET EBIPA SERVER DOMAIN "byggtjanst.local" 1B ADD EBIPA SERVER DNS 10.0.209.30 1B ADD EBIPA SERVER DNS 10.0.209.31 1B DISABLE EBIPA SERVER 1B SET EBIPA SERVER NONE NONE 2 SET EBIPA SERVER GATEWAY 10.0.209.1 2 SET EBIPA SERVER DOMAIN "byggtjanst.local" 2 ADD EBIPA SERVER DNS 10.0.209.30 2 ADD EBIPA SERVER DNS 10.0.209.31 2 DISABLE EBIPA SERVER 2 SET EBIPA SERVER NONE NONE 2A SET EBIPA SERVER GATEWAY 10.0.209.1 2A SET EBIPA SERVER DOMAIN "byggtjanst.local" 2A ADD EBIPA SERVER DNS 10.0.209.30 2A ADD EBIPA SERVER DNS 10.0.209.31 2A DISABLE EBIPA SERVER 2A SET EBIPA SERVER NONE NONE 2B SET EBIPA SERVER GATEWAY 10.0.209.1 2B SET EBIPA SERVER DOMAIN "byggtjanst.local" 2B ADD EBIPA SERVER DNS 10.0.209.30 2B ADD EBIPA SERVER DNS 10.0.209.31 2B DISABLE EBIPA SERVER 2B SET EBIPA SERVER NONE NONE 3 SET EBIPA SERVER GATEWAY 10.0.209.1 3 SET EBIPA SERVER DOMAIN "byggtjanst.local" 3 ADD EBIPA SERVER DNS 10.0.209.30 3 ADD EBIPA SERVER DNS 10.0.209.31 3 DISABLE EBIPA SERVER 3 SET EBIPA SERVER NONE NONE 3A SET EBIPA SERVER GATEWAY 10.0.209.1 3A SET EBIPA SERVER DOMAIN "byggtjanst.local" 3A ADD EBIPA SERVER DNS 10.0.209.30 3A ADD EBIPA SERVER DNS 10.0.209.31 3A DISABLE EBIPA SERVER 3A SET EBIPA SERVER NONE NONE 3B SET EBIPA SERVER GATEWAY 10.0.209.1 3B SET EBIPA SERVER DOMAIN "byggtjanst.local" 3B ADD EBIPA SERVER DNS 10.0.209.30 3B ADD EBIPA SERVER DNS 10.0.209.31 3B DISABLE EBIPA SERVER 3B SET EBIPA SERVER NONE NONE 4 SET EBIPA SERVER GATEWAY 10.0.209.1 4 SET EBIPA SERVER DOMAIN "byggtjanst.local" 4 ADD EBIPA SERVER DNS 10.0.209.30 4 ADD EBIPA SERVER DNS 10.0.209.31 4 DISABLE EBIPA SERVER 4 SET EBIPA SERVER NONE NONE 4A SET EBIPA SERVER GATEWAY 10.0.209.1 4A SET EBIPA SERVER DOMAIN "byggtjanst.local" 4A ADD EBIPA SERVER DNS 10.0.209.30 4A ADD EBIPA SERVER DNS 10.0.209.31 4A DISABLE EBIPA SERVER 4A SET EBIPA SERVER NONE NONE 4B SET EBIPA SERVER GATEWAY 10.0.209.1 4B SET EBIPA SERVER DOMAIN "byggtjanst.local" 4B ADD EBIPA SERVER DNS 10.0.209.30 4B ADD EBIPA SERVER DNS 10.0.209.31 4B DISABLE EBIPA SERVER 4B SET EBIPA SERVER 10.0.209.85 255.255.255.0 5 SET EBIPA SERVER GATEWAY 10.0.209.1 5 SET EBIPA SERVER DOMAIN "byggtjanst.local" 5 ADD EBIPA SERVER DNS 10.0.209.30 5 ADD EBIPA SERVER DNS 10.0.209.31 5 ENABLE EBIPA SERVER 5 SET EBIPA SERVER NONE NONE 5A SET EBIPA SERVER GATEWAY 10.0.209.1 5A SET EBIPA SERVER DOMAIN "byggtjanst.local" 5A ADD EBIPA SERVER DNS 10.0.209.30 5A ADD EBIPA SERVER DNS 10.0.209.31 5A DISABLE EBIPA SERVER 5A SET EBIPA SERVER NONE NONE 5B SET EBIPA SERVER GATEWAY 10.0.209.1 5B SET EBIPA SERVER DOMAIN "byggtjanst.local" 5B ADD EBIPA SERVER DNS 10.0.209.30 5B ADD EBIPA SERVER DNS 10.0.209.31 5B DISABLE EBIPA SERVER 5B SET EBIPA SERVER NONE NONE 6 SET EBIPA SERVER GATEWAY 10.0.209.1 6 SET EBIPA SERVER DOMAIN "byggtjanst.local" 6 ADD EBIPA SERVER DNS 10.0.209.30 6 ADD EBIPA SERVER DNS 10.0.209.31 6 DISABLE EBIPA SERVER 6 SET EBIPA SERVER NONE NONE 6A SET EBIPA SERVER GATEWAY 10.0.209.1 6A SET EBIPA SERVER DOMAIN "byggtjanst.local" 6A ADD EBIPA SERVER DNS 10.0.209.30 6A ADD EBIPA SERVER DNS 10.0.209.31 6A DISABLE EBIPA SERVER 6A SET EBIPA SERVER NONE NONE 6B SET EBIPA SERVER GATEWAY 10.0.209.1 6B SET EBIPA SERVER DOMAIN "byggtjanst.local" 6B ADD EBIPA SERVER DNS 10.0.209.30 6B ADD EBIPA SERVER DNS 10.0.209.31 6B DISABLE EBIPA SERVER 6B SET EBIPA SERVER NONE NONE 7 SET EBIPA SERVER GATEWAY 10.0.209.1 7 SET EBIPA SERVER DOMAIN "byggtjanst.local" 7 ADD EBIPA SERVER DNS 10.0.209.30 7 ADD EBIPA SERVER DNS 10.0.209.31 7 DISABLE EBIPA SERVER 7 SET EBIPA SERVER NONE NONE 7A SET EBIPA SERVER GATEWAY 10.0.209.1 7A SET EBIPA SERVER DOMAIN "byggtjanst.local" 7A ADD EBIPA SERVER DNS 10.0.209.30 7A ADD EBIPA SERVER DNS 10.0.209.31 7A DISABLE EBIPA SERVER 7A SET EBIPA SERVER NONE NONE 7B SET EBIPA SERVER GATEWAY 10.0.209.1 7B SET EBIPA SERVER DOMAIN "byggtjanst.local" 7B ADD EBIPA SERVER DNS 10.0.209.30 7B ADD EBIPA SERVER DNS 10.0.209.31 7B DISABLE EBIPA SERVER 7B SET EBIPA SERVER NONE NONE 8 SET EBIPA SERVER GATEWAY 10.0.209.1 8 SET EBIPA SERVER DOMAIN "byggtjanst.local" 8 ADD EBIPA SERVER DNS 10.0.209.30 8 ADD EBIPA SERVER DNS 10.0.209.31 8 DISABLE EBIPA SERVER 8 SET EBIPA SERVER NONE NONE 8A SET EBIPA SERVER GATEWAY 10.0.209.1 8A SET EBIPA SERVER DOMAIN "byggtjanst.local" 8A ADD EBIPA SERVER DNS 10.0.209.30 8A ADD EBIPA SERVER DNS 10.0.209.31 8A DISABLE EBIPA SERVER 8A SET EBIPA SERVER NONE NONE 8B SET EBIPA SERVER GATEWAY 10.0.209.1 8B SET EBIPA SERVER DOMAIN "byggtjanst.local" 8B ADD EBIPA SERVER DNS 10.0.209.30 8B ADD EBIPA SERVER DNS 10.0.209.31 8B DISABLE EBIPA SERVER 8B #Set Enclosure Bay IP Addressing (EBIPA) Information for Interconnect Bays #NOTE: SET EBIPA commands are only valid for OA v3.00 and later SET EBIPA INTERCONNECT 10.0.209.68 255.255.255.0 1 SET EBIPA INTERCONNECT GATEWAY 10.0.209.1 1 SET EBIPA INTERCONNECT DOMAIN "byggtjanst.local" 1 ADD EBIPA INTERCONNECT DNS 10.0.209.30 1 ADD EBIPA INTERCONNECT DNS 10.0.209.31 1 SET EBIPA INTERCONNECT NTP PRIMARY NONE 1 SET EBIPA INTERCONNECT NTP SECONDARY NONE 1 ENABLE EBIPA INTERCONNECT 1 SET EBIPA INTERCONNECT NONE NONE 2 SET EBIPA INTERCONNECT GATEWAY 10.0.209.1 2 SET EBIPA INTERCONNECT DOMAIN "byggtjanst.local" 2 ADD EBIPA INTERCONNECT DNS 10.0.209.30 2 ADD EBIPA INTERCONNECT DNS 10.0.209.31 2 SET EBIPA INTERCONNECT NTP PRIMARY NONE 2 SET EBIPA INTERCONNECT NTP SECONDARY NONE 2 DISABLE EBIPA INTERCONNECT 2 SET EBIPA INTERCONNECT NONE NONE 3 SET EBIPA INTERCONNECT GATEWAY 10.0.209.1 3 SET EBIPA INTERCONNECT DOMAIN "byggtjanst.local" 3 ADD EBIPA INTERCONNECT DNS 10.0.209.30 3 ADD EBIPA INTERCONNECT DNS 10.0.209.31 3 SET EBIPA INTERCONNECT NTP PRIMARY NONE 3 SET EBIPA INTERCONNECT NTP SECONDARY NONE 3 DISABLE EBIPA INTERCONNECT 3 SET EBIPA INTERCONNECT NONE NONE 4 SET EBIPA INTERCONNECT GATEWAY 10.0.209.1 4 SET EBIPA INTERCONNECT DOMAIN "byggtjanst.local" 4 ADD EBIPA INTERCONNECT DNS 10.0.209.30 4 ADD EBIPA INTERCONNECT DNS 10.0.209.31 4 SET EBIPA INTERCONNECT NTP PRIMARY NONE 4 SET EBIPA INTERCONNECT NTP SECONDARY NONE 4 DISABLE EBIPA INTERCONNECT 4 SAVE EBIPA #Uncomment following line to remove all user accounts currently in the system #REMOVE USERS ALL #Create Users ADD USER "Administrator" SET USER CONTACT "Administrator" "" SET USER FULLNAME "Administrator" "System Administrator" SET USER ACCESS "Administrator" ADMINISTRATOR ASSIGN SERVER 1,2,3,4,5,6,7,8,1A,2A,3A,4A,5A,6A,7A,8A,1B,2B,3B,4B,5B,6B,7B,8B "Administrator" ASSIGN INTERCONNECT 1,2,3,4 "Administrator" ASSIGN OA "Administrator" ENABLE USER "Administrator" #Password Settings DISABLE STRONG PASSWORDS SET MINIMUM PASSWORD LENGTH 3 #Session Timeout Settings SET SESSION TIMEOUT 0 #Set LDAP Information SET LDAP SERVER SET LDAP PORT 0 SET LDAP NAME MAP OFF SET LDAP SEARCH 1 "" SET LDAP SEARCH 2 "" SET LDAP SEARCH 3 "" SET LDAP SEARCH 4 "" SET LDAP SEARCH 5 "" SET LDAP SEARCH 6 "" #Uncomment following line to remove all LDAP accounts currently in the system #REMOVE LDAP GROUP ALL DISABLE LDAP #Set SSO TRUST MODE SET SSO TRUST Disabled SET SERIAL BAUD 9600 #Set VLAN Information SET VLAN FACTORY SET VLAN DEFAULT 1 EDIT VLAN 1 "Default" SET VLAN SERVER 1 1 SET VLAN SERVER 1 2 SET VLAN SERVER 1 3 SET VLAN SERVER 1 4 SET VLAN SERVER 1 5 SET VLAN SERVER 1 6 SET VLAN SERVER 1 7 SET VLAN SERVER 1 8 SET VLAN INTERCONNECT 1 1 SET VLAN INTERCONNECT 1 2 SET VLAN INTERCONNECT 1 3 SET VLAN INTERCONNECT 1 4 SET VLAN OA 1 DISABLE VLAN SAVE VLAN #Set URB Information DISABLE URB SET URB URL "" SET URB PROXY URL "" SET URB INTERVAL DAILY 0 SET SOLUTIONSID "0000000000000000" #Set Login Banner Text Information CLEAR LOGIN_BANNER_TEXT DISABLE LOGIN_BANNER #Set Firmware Management information DISABLE FIRMWARE MANAGEMENT SET FIRMWARE MANAGEMENT POLICY MANUAL SET FIRMWARE MANAGEMENT POWER OFF SET FIRMWARE MANAGEMENT SCHEDULE NONE SET FIRWMARE MANAGEMENT BAYS_TO_INCLUDE SERVER NONE #Set Remote Support Information DISABLE REMOTE_SUPPORT #Set Network Information #NOTE: Setting your network information through a script while # remotely accessing the server could drop your connection. # If your connection is dropped this script may not execute to conclusion. SET OA NAME 1 OA-BYGGBLADE SET IPCONFIG STATIC 1 192.168.16.16 255.255.255.0 0.0.0.0 0.0.0.0 0.0.0.0 SET NIC AUTO 1 DISABLE ROUTER ADVERTISEMENTS DISABLE DHCPV6 DISABLE IPV6 >SHOW DATE Date: 2015-10-15T09:16:43-01:00 Time Zone: Etc/GMT+1 >SHOW DISPLAY EVENT Display Events is set to OFF. >SHOW EBIPA EBIPA Device Server Settings Bay Enabled EBIPA/Current Netmask Gateway DNS Domain --- ------- --------------- --------------- --------------- --------------- ------ 1 Yes 10.0.209.83 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 1A No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 1B No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 2 No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 0.0.0.0 10.0.209.31 2A No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 2B No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 3 No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 3A No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 3B No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 4 No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 4A No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 4B No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 5 Yes 10.0.209.85 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 5A No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 5B No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 6 No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 6A No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 6B No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 7 No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 7A No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 7B No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 8 No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 8A No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 8B No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 EBIPA Device Interconnect Settings Bay Enabled EBIPA/Current Netmask Gateway DNS NTP Domain --- ------- --------------- --------------- --------------- --------------- --------------- ------ 1 Yes 10.0.209.68 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.68 10.0.209.31 2 No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.41 10.0.209.31 3 No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 4 No 255.255.255.0 10.0.209.1 10.0.209.30 byggtjanst.local 10.0.209.31 >SHOW ENCLOSURE FAN ALL Fan #1 information: Status: OK Speed: 27 percent of Maximum speed Maximum speed: 18000 Minimum speed: 10 Power consumed: 7 Product Name: Active Cool 200 Fan Part Number: 412140-B21 Spare Part Number: 413996-001 Version: 2.9 Diagnostic Status: Internal Data OK Location OK Device Failure OK Device Degraded OK Missing Device OK Fan #2 information: Status: OK Speed: 27 percent of Maximum speed Maximum speed: 18000 Minimum speed: 10 Power consumed: 7 Product Name: Active Cool 200 Fan Part Number: 412140-B21 Spare Part Number: 413996-001 Version: 2.9 Diagnostic Status: Internal Data OK Location OK Device Failure OK Device Degraded OK Missing Device OK Fan #3 information: Status: OK Speed: 27 percent of Maximum speed Maximum speed: 18000 Minimum speed: 10 Power consumed: 6 Product Name: Active Cool 200 Fan Part Number: 412140-B21 Spare Part Number: 413996-001 Version: 2.9 Diagnostic Status: Internal Data OK Location OK Device Failure OK Device Degraded OK Missing Device OK Fan #4 information: Status: OK Speed: 27 percent of Maximum speed Maximum speed: 18000 Minimum speed: 10 Power consumed: 7 Product Name: Active Cool 200 Fan Part Number: 412140-B21 Spare Part Number: 413996-001 Version: 2.9 Diagnostic Status: Internal Data OK Location OK Device Failure OK Device Degraded OK Missing Device OK Fan #5 information: Status: OK Speed: 27 percent of Maximum speed Maximum speed: 18000 Minimum speed: 10 Power consumed: 7 Product Name: Active Cool 200 Fan Part Number: 412140-B21 Spare Part Number: 413996-001 Version: 2.9 Diagnostic Status: Internal Data OK Location OK Device Failure OK Device Degraded OK Missing Device OK Fan #6 information: Status: OK Speed: 27 percent of Maximum speed Maximum speed: 18000 Minimum speed: 10 Power consumed: 6 Product Name: Active Cool 200 Fan Part Number: 412140-B21 Spare Part Number: 413996-001 Version: 2.9 Diagnostic Status: Internal Data OK Location OK Device Failure OK Device Degraded OK Missing Device OK >SHOW ENCLOSURE INFO Enclosure Information: Enclosure Name: CZC8383004 Enclosure Type: BladeSystem c3000 Enclosure Part Number: 437502-B21 Serial Number: CZC8383004 UUID: 09CZC8383004 Asset Tag: Midplane Spare Part Number: 441829-001 Solutions ID: 0000000000000000 Power Distribution Unit: [No PDU is present on c3000 enclosures] Onboard Administrator Tray Information: [No Tray Information is present on c3000 enclosures] >SHOW ENCLOSURE LCD Status : OK Display : On Name : BladeSystem c3000 Insight Display Spare Part# : 441831-001 Manufacturer: HP Fw Version : 2.2.2 Diagnostic Status: Internal Data OK >SHOW ENCLOSURE POWER_CAP Enclosure Dynamic Power Cap: Disabled Derated Circuit Capacity: Disabled Rated Circuit Capacity: Disabled Allowable Enclosure Dynamic Power Cap: 820 - 1459 Watts AC Allowable Derated Circuit Capacity: 820 - 1459 Watts AC Allowable Rated Circuit Capacity: 820 - 1459 Watts AC >SHOW ENCLOSURE POWER_CAP_BAYS_TO_EXCLUDE Bays opted out: None >SHOW ENCLOSURE POWERSUPPLY ALL Power Supply #1 Information: Status: Failed AC Input Status: Failed Capacity: 0 Watts Current Power Output: 0 Watts Serial Number: 531290A4DW650P Product Name: HP PROLIANT SERVER PS Part Number: 437572-B21 Spare Part Number: 441830-001 Product Ver: 01 Diagnostic Status: Device Failure Failed Power Cord Failed Power Supply #2 Information: Status: OK AC Input Status: OK Capacity: 1200 Watts Current Power Output: 30 Watts Serial Number: 531290A4DW96UL Product Name: HP PROLIANT SERVER PS Part Number: 437572-B21 Spare Part Number: 441830-001 Product Ver: 01 Diagnostic Status: Internal Data OK Device Failure OK Power Cord OK Power Supply #3 Information: Status: Power Supply Bay Empty Power Supply #4 Information: Status: Failed AC Input Status: Failed Capacity: 0 Watts Current Power Output: 0 Watts Serial Number: 531290A4DWJ1NR Product Name: HP PROLIANT SERVER PS Part Number: 437572-B21 Spare Part Number: 441830-001 Product Ver: 01 Diagnostic Status: Device Failure Failed Power Cord Failed Power Supply #5 Information: Status: OK AC Input Status: OK Capacity: 1200 Watts Current Power Output: 38 Watts Serial Number: 531290A4DW96UN Product Name: HP PROLIANT SERVER PS Part Number: 437572-B21 Spare Part Number: 441830-001 Product Ver: 01 Diagnostic Status: Internal Data OK Device Failure OK Power Cord OK Power Supply #6 Information: Status: Power Supply Bay Empty >SHOW ENCLOSURE POWER_SUMMARY Enclosure Bay Output Allocation: Bay Power Allocated (Watts DC) ------------- -------------------------- Devices 0 Interconnects + 60 Fans + 480 ------- = 540 Enclosure Output Power Summary: Enclosure Watts DC ---------------- -------- Power Capacity 1200 Power Allocation - 540 Power Available = 660 Enclosure Input Power Summary: Enclosure Watts AC ----------------- -------- Present Power 181 Max Input Power 1459 Dynamic Power Cap Not Set Power Limit Not Set Device Bay Power Summary: Power Allocated Bay Name (Watts DC) --- ------------------- --------------- 2 HP StorageWorks SB4 0 ------- = 0 Interconnect Bay Power Summary: Bay Name Power Allocated (Watts DC) --- -------------------------------- -------------------------- 1 GbE2c Ethernet Blade Switch 25 2 Brocade 4/12 SAN Switch for HP 35 ------- = 60 Fan Power Summary: Total Fans Fan Rule Present Power Power Allocated (Number of Fans) (Number of Fans) (Watts DC) (Watts DC) ---------------- ---------------- -------------- --------------- 6 4 40 480 >SHOW ENCLOSURE STATUS Enclosure: Status: Degraded Unit Identification LED: Off Diagnostic Status: Internal Data OK Onboard Administrator: Status: OK Power Subsystem: Status: Degraded Power Mode: Redundant Redundancy State: Redundant Power Capacity: 1200 Watts DC Power Available: 660 Watts DC Present Power: 181 Watts AC Cooling Subsystem: Status: OK Fans Good/Wanted/Needed: 6/4/3 Fan 1: 5001 RPM (28%) Fan 2: 4999 RPM (28%) Fan 3: 5001 RPM (28%) Fan 4: 5000 RPM (28%) Fan 5: 5000 RPM (28%) Fan 6: 5000 RPM (28%) >SHOW ENCLOSURE TEMP Locale Bay # Temp Status Temp Caution Critical ---------------------- ----- ----------- -------- ------- -------- Enclosure N/A 25C/ 77F --- --- Onboard Administrator 1 OK 25C/ 77F 75C 80C Blade Bay 2 N/A 0C/ 32F 45C 60C Interconnect Module 1 OK ---- --- --- Interconnect Module 2 OK ---- --- --- >SHOW FIPS MODE FIPS Mode is Off >SHOW OA INFO Onboard Administrator #1 information: Product Name : BladeSystem c3000 Onboard Administrator Part Number : 448589-B21 Spare Part No.: 441832-001 Serial Number : P3059%%9VW909F UUID : 18P3059%%9VW909F Manufacturer : HP Firmware Ver. : 3.71 Dec 07 2012 Hw Board Type : 1 Hw Version : %% Loader Version: U-Boot 1.1.1 (Aug 21 2007 - 09:51:44) Serial Port: Baud Rate : 9600 Parity : None Data bits : 8 Stop bits : 1 Flow control: None >SHOW OA NETWORK Enclosure Network Settings: - - - - - IPv6 Information - - - - - IPv6: Disabled DHCPv6: Disabled Router Advertisement: Disabled Onboard Administrator #1 Network Information: Name: OA-BYGGBLADE - - - - - IPv4 Information - - - - - DHCP: Disabled IPv4 Address: 192.168.16.16 Netmask: 255.255.255.0 Gateway Address: 0.0.0.0 - - - - - IPv6 Information - - - - - Static Address: Not Set Static IPv6 DNS 1: Not Set Static IPv6 DNS 2: Not Set - - - - - General Information - - - - - Active DNS Addresses: Primary: Not Set Secondary: Not Set Tertiary: Not Set MAC Address: 00:1F:29:E7:24:0D Link Settings: Auto-Negotiation, 10 Mbps, Half Duplex Link Status: Not Active Enclosure IP Mode: Not Supported >SHOW OA STATUS ALL Onboard Administrator #1 Status: Name: OA-BYGGBLADE Role: Active UID: Off Status: OK >SHOW OA UPTIME ALL Onboard Administrator #1: Role : Active Uptime : 0 days, 0 hours, 24 min CPU Load : 0.12, 0.20, 0.18 >SHOW OA CERTIFICATE Onboard Administrator #1 Certificate Information: Issued by: CZC8383004 Valid from: 2006-09-06T00:18:19Z Valid until: 2016-09-03T00:18:19Z Serial Number: C8:88:B2:68:A1:8E:2B:CE Version: 1 MD5 Fingerprint: 09:2B:D0:D4:70:8E:5F:C0:71:D1:B7:37:C9:D2:8A:97 SHA1 Fingerprint: 54:CE:1D:C6:B0:3E:02:CD:06:98:88:BC:93:87:B7:CA:2E:46:7C:29 Public Key: RSA (1024 Bits) Subject: Common Name (CN): CZC8383004 Country (C): State or Province (ST): City or Locality (L): Organization Name (0): Hewlett-Packard Organizational Unit: Onboard Administrator >SHOW SYSLOG OA 1 Mar 10 13:44:40 OA: Blade 3 is reporting nominal health status. Mar 10 13:44:40 OA: Blade in bay #3 status changed to OK Mar 10 13:44:52 Kernel: usb 2-2: device descriptor read/64, error -71 Mar 10 13:44:54 Kernel: hub 2-0:1.0: Cannot enable port 2. Maybe the USB cable is bad? Mar 10 13:44:56 OA: Internal health status of interconnect in bay 2 changed to OK Mar 10 13:44:59 OA: Device 3 power delayed until device settings are updated. Mar 10 13:45:12 OA: Blade removed from bay 3 Mar 10 13:47:41 OA: Blade in bay #6 status changed to OK Mar 10 13:51:43 OA: Blade in bay #6 status changed to OK Mar 26 09:00:39 OA: Administrator logged into the Onboard Administrator from 10.0.209.187 Mar 26 09:14:16 OA: Blade in bay 6 has been powered down Mar 26 09:14:21 OA: Blade removed from bay 6 Mar 26 11:54:05 OA: Administrator logged into the Onboard Administrator from 10.0.209.187 Mar 28 09:10:31 OA: Administrator logged into the Onboard Administrator from 10.0.209.136 Mar 28 09:26:27 OA: Administrator logged into the Onboard Administrator from 10.0.209.136 Mar 28 10:36:18 OA: Administrator logged into the Onboard Administrator from 10.0.209.135 Mar 31 06:32:25 OA: Authentication failure for user admin from 10.0.209.204, requesting web service Mar 31 06:32:41 OA: Administrator logged into the Onboard Administrator from 10.0.209.204 Apr 15 16:27:39 OA: Blade in bay 1 has been powered down Apr 15 16:27:39 OA: Blade in bay 2 has been powered down Apr 15 16:27:48 OA: Blade 2 found a partner device. Apr 15 16:27:48 OA: Blade 1 found a partner device. Apr 15 16:27:48 OA: Blade 2 properly partners with its neighbor. Apr 15 16:27:48 OA: Blade 1 properly partners with its neighbor. Apr 15 16:27:48 OA: Blade in bay 2 has been powered on Apr 15 16:27:49 OA: Blade in bay #2 status changed from Degraded to OK Apr 15 19:01:53 OA: PS Subsystem N + N Redundancy - FAILED. Allocated Power: 640W DC, Present Power: 76W AC. Apr 15 19:01:53 OA: Enclosure Status changed from OK to Degraded. (Power Subsystem) Apr 15 19:02:22 OA: PS Status Changed: Bay #1 From: unknown To: failed Apr 15 19:02:22 OA: PS Status Changed: Bay #2 From: unknown To: failed Apr 15 19:03:10 NTP: Failed to update time/date using NTP Apr 15 19:50:33 Kernel: Network link is down Apr 15 22:09:17 Kernel: Network link is up at 100Mbps - Full Duplex Apr 15 22:09:21 OA: Time zone changed to GMT+1 Apr 15 22:09:23 OA: Blade in bay #1 status changed to Unknown Apr 15 22:09:23 OA: Blade in bay #2 status changed to Unknown Apr 15 22:09:23 OA: LCD Status is: OK. Apr 15 22:09:24 OA: Blade in bay #2 status changed to OK Apr 15 22:09:24 OA: Blade 1 is reporting nominal health status. Apr 15 22:09:24 OA: Blade in bay #1 status changed to OK Apr 15 22:09:27 Enclosure-Link: Service started Apr 15 22:09:27 OA: Device 2 power delayed during device discovery. Apr 15 22:09:28 NTP: Failed to update time/date using NTP Apr 15 22:09:32 OA: Device 1 power delayed during device discovery. Apr 15 22:09:33 Enclosure-Link: Initial topology scan completed successfully Apr 15 22:09:37 OA: Onboard Administrator booted successfully Apr 15 22:09:44 OA: HTTP server is up Apr 15 22:10:09 NTP: Successfully updated time/date using NTP Apr 15 22:10:16 OA: VLAN is disabled Apr 15 22:10:25 OA: Blade in bay #1 status changed to OK Apr 15 22:10:28 OA: Blade 2 found a partner device. Apr 15 22:10:28 OA: Blade 1 found a partner device. Apr 15 22:10:28 OA: Blade 2 properly partners with its neighbor. Apr 15 22:10:28 OA: Blade 1 properly partners with its neighbor. Apr 15 22:10:28 OA: Blade 2 is properly cooled. Apr 15 22:10:28 OA: Blade in bay 2 has been powered on Apr 15 22:10:28 OA: Blade 2 is reporting nominal health status. Apr 15 22:10:41 OA: Blade 1 is properly cooled. Apr 15 22:10:41 OA: Blade in bay 1 has been powered on Apr 15 22:11:12 OA: Internal health status of interconnect in bay 2 changed to OK May 12 12:03:37 Kernel: hub 4-0:1.0: Cannot enable port 2. Maybe the USB cable is bad? May 12 12:03:40 Kernel: hub 4-0:1.0: Cannot enable port 2. Maybe the USB cable is bad? May 12 12:03:43 Kernel: hub 4-0:1.0: Cannot enable port 2. Maybe the USB cable is bad? May 12 12:03:46 Kernel: hub 4-0:1.0: Cannot enable port 2. Maybe the USB cable is bad? Jul 27 10:22:00 OA: PS Subsystem N + N Redundancy - FAILED. Allocated Power: 956W DC, Present Power: 250W AC. Jul 27 10:22:00 OA: Enclosure Status changed from OK to Degraded. (Power Subsystem) Jul 27 10:22:00 OA: PS Subsystem N + N Redundancy - REPAIRED Jul 27 10:22:00 OA: Enclosure Status changed from Degraded to OK. Jul 31 20:07:52 Kernel: usb 2-2: device descriptor read/64, error -110 Jul 31 20:07:54 Kernel: hub 2-0:1.0: Cannot enable port 2. Maybe the USB cable is bad? Jul 31 20:07:55 Kernel: hub 2-0:1.0: Cannot enable port 2. Maybe the USB cable is bad? Jul 31 20:07:56 Kernel: usb 2-2: device descriptor read/8, error -71 Jul 31 20:07:56 Kernel: usb 2-2: device descriptor read/8, error -71 Jul 31 20:07:56 Kernel: usb 2-2: device not accepting address 7, error -71 Aug 6 04:44:07 Kernel: usb 2-2: device descriptor read/64, error -110 Aug 6 04:44:12 Kernel: usb 2-2: device descriptor read/64, error -71 Aug 6 04:44:13 Kernel: hub 2-0:1.0: Cannot enable port 2. Maybe the USB cable is bad? Aug 6 04:44:14 Kernel: usb 2-2: device descriptor read/8, error -71 Aug 6 04:44:14 Kernel: usb 2-2: device descriptor read/8, error -71 Aug 6 04:44:17 Kernel: usb 2-2: device descriptor read/8, error -71 Aug 6 04:44:17 Kernel: usb 2-2: device descriptor read/8, error -71 Aug 6 23:11:54 Kernel: usb 2-2: device descriptor read/64, error -110 Aug 6 23:12:10 Kernel: usb 2-2: device descriptor read/64, error -110 Aug 6 23:12:13 Kernel: usb 2-2: device descriptor read/64, error -110 Aug 6 23:12:28 Kernel: usb 2-2: device descriptor read/64, error -110 Aug 6 23:12:33 Kernel: usb 2-2: device descriptor read/8, error -110 Aug 6 23:12:34 Kernel: usb 2-2: device descriptor read/8, error -71 Aug 6 23:12:37 Kernel: usb 2-2: device descriptor read/8, error -71 Aug 6 23:12:37 Kernel: usb 2-2: device descriptor read/8, error -71 Aug 7 03:25:01 OA: PS Subsystem N + N Redundancy - FAILED. Allocated Power: 956W DC, Present Power: 250W AC. Aug 7 03:25:01 OA: Enclosure Status changed from OK to Degraded. (Power Subsystem) Aug 7 03:25:08 OA: PS Subsystem N + N Redundancy - REPAIRED Aug 7 03:25:08 OA: Enclosure Status changed from Degraded to OK. Aug 7 03:52:08 Kernel: usb 2-2: device descriptor read/64, error -110 Aug 7 03:52:23 Kernel: usb 2-2: device descriptor read/64, error -110 Aug 7 03:52:26 Kernel: usb 2-2: device descriptor read/64, error -110 Aug 7 03:52:37 Kernel: usb 2-2: device descriptor read/64, error -71 Aug 7 03:52:42 Kernel: usb 2-2: device descriptor read/8, error -110 Aug 7 03:52:47 Kernel: usb 2-2: device descriptor read/8, error -110 Aug 7 03:52:52 Kernel: usb 2-2: device descriptor read/8, error -110 Aug 7 03:52:56 Kernel: usb 2-2: device descriptor read/8, error -71 Aug 8 04:37:49 Kernel: usb 2-2: device descriptor read/64, error -110 Aug 8 04:38:04 Kernel: usb 2-2: device descriptor read/64, error -110 Aug 8 04:38:08 Kernel: usb 2-2: device descriptor read/64, error -110 Aug 8 04:38:23 Kernel: usb 2-2: device descriptor read/64, error -110 Aug 8 04:38:28 Kernel: usb 2-2: device descriptor read/8, error -110 Aug 8 04:38:33 Kernel: usb 2-2: device descriptor read/8, error -110 Aug 8 04:38:39 Kernel: usb 2-2: device descriptor read/8, error -110 Aug 8 04:38:44 Kernel: usb 2-2: device descriptor read/8, error -110 Aug 9 05:54:25 Kernel: hub 2-0:1.0: Cannot enable port 2. Maybe the USB cable is bad? Aug 9 05:54:28 Kernel: hub 2-0:1.0: Cannot enable port 2. Maybe the USB cable is bad? Aug 9 05:54:31 Kernel: usb 2-2: device descriptor read/64, error -110 Aug 9 05:54:35 Kernel: hub 2-0:1.0: Cannot enable port 2. Maybe the USB cable is bad? Aug 9 05:54:38 Kernel: usb 2-2: device descriptor read/8, error -71 Aug 9 05:54:42 Kernel: usb 2-2: device descriptor read/8, error -71 Aug 9 05:54:43 Kernel: usb 2-2: device not accepting address 29, error -71 Aug 9 06:56:39 Kernel: usb 2-2: device descriptor read/64, error -110 Aug 9 06:56:44 Kernel: usb 2-2: device descriptor read/64, error -110 Aug 9 06:56:54 Kernel: usb 2-2: device descriptor read/64, error -71 Aug 9 06:56:59 Kernel: usb 2-2: device descriptor read/64, error -110 Sep 21 12:52:50 OA: PS Subsystem N + N Redundancy - FAILED. Allocated Power: 956W DC, Present Power: 235W AC. Sep 21 12:52:50 OA: Enclosure Status changed from OK to Degraded. (Power Subsystem) Sep 21 12:52:57 OA: PS Subsystem N + N Redundancy - REPAIRED Sep 21 12:52:57 OA: Enclosure Status changed from Degraded to OK. Oct 9 13:23:42 OA: Authentication failure for user admin from 10.0.209.153, requesting web service Oct 9 13:23:55 OA: Administrator logged into the Onboard Administrator from 10.0.209.153 Oct 14 06:32:59 OA: Authentication failure for user administrator from 10.0.209.212, requesting web service Oct 14 06:33:11 OA: Administrator logged into the Onboard Administrator from 10.0.209.212 Nov 13 14:01:14 OA: Authentication failure for user admin from 10.0.209.95, requesting web service Nov 13 14:01:24 OA: Administrator logged into the Onboard Administrator from 10.0.209.95 Nov 16 18:05:02 OA: Administrator logged into the Onboard Administrator from 10.0.210.240 Nov 16 18:20:57 OA: Administrator logged into the Onboard Administrator from 10.0.209.95 Nov 16 18:32:57 OA: Administrator logged into the Onboard Administrator from 10.0.209.95 Nov 17 11:41:04 OA: Authentication failure for user administrator from 10.0.209.95, requesting web service Nov 17 12:13:52 OA: Authentication failure for user Administrator from 10.0.209.95, requesting web service Nov 17 12:14:00 OA: Administrator logged into the Onboard Administrator from 10.0.209.95 Nov 19 13:53:33 OA: Authentication failure for user admin from 10.0.210.106, requesting web service Nov 19 13:53:44 OA: Authentication failure for user Admin from 10.0.210.106, requesting web service Nov 19 13:53:53 OA: Administrator logged into the Onboard Administrator from 10.0.210.106 Nov 19 15:02:44 OA: Authentication failure for user admin from 10.0.209.95, requesting web service Nov 19 15:02:56 OA: Administrator logged into the Onboard Administrator from 10.0.209.95 Nov 20 19:59:20 OA: Authentication failure for user admin from 10.0.209.95, requesting web service Nov 20 19:59:34 OA: Administrator logged into the Onboard Administrator from 10.0.209.95 Nov 20 20:09:52 OA: Administrator logged out of the Onboard Administrator Nov 28 08:42:40 OA: Administrator logged into the Onboard Administrator from 10.0.209.95 Nov 28 08:45:15 OA: Blade in bay 1 has been powered down Nov 28 08:45:15 OA: Blade in bay 2 has been powered down Nov 28 08:45:21 OA: Blade 2 found a partner device. Nov 28 08:45:21 OA: Blade 1 found a partner device. Nov 28 08:45:21 OA: Blade 2 properly partners with its neighbor. Nov 28 08:45:21 OA: Blade 1 properly partners with its neighbor. Nov 28 08:45:21 OA: Blade in bay 2 has been powered on Nov 28 08:50:18 OA: Onboard Administrator in bay 1 was restarted by user Administrator. Nov 28 08:50:24 OA: Onboard Administrator is rebooting Nov 28 08:51:22 Kernel: Network link is up at 100Mbps - Full Duplex Nov 28 08:51:25 OA: Time zone changed to GMT+1 Nov 28 08:51:27 OA: Blade in bay #1 status changed to Unknown Nov 28 08:51:27 OA: Blade in bay #2 status changed to Unknown Nov 28 08:51:28 OA: LCD Status is: OK. Nov 28 08:51:28 OA: Blade 1 is reporting nominal health status. Nov 28 08:51:29 OA: Blade in bay #1 status changed to OK Nov 28 08:51:31 Enclosure-Link: Service started Nov 28 08:51:38 NTP: Successfully updated time/date using NTP Nov 28 08:51:42 Enclosure-Link: Initial topology scan completed successfully Nov 28 08:51:47 OA: Onboard Administrator booted successfully Nov 28 08:51:49 OA: Fan Removed: Bay #3 Nov 28 08:51:53 OA: Fan Inserted: Bay #3 Nov 28 08:51:54 OA: HTTP server is up Nov 28 08:51:59 OA: Blade 2 is reporting nominal health status. Nov 28 08:52:00 OA: Blade in bay #2 status changed to OK Nov 28 08:52:03 OA: Blade in bay #1 status changed to OK Nov 28 08:52:27 OA: VLAN is disabled Nov 28 08:54:02 OA: Authentication failure for user administrator from 10.0.209.95, requesting web service Nov 28 08:54:18 OA: Administrator logged into the Onboard Administrator from 10.0.209.95 Nov 28 09:21:38 Kernel: Network link is down Nov 28 09:28:09 NTP: Failed to update time/date using NTP Nov 28 09:45:24 OA: PS Removed: Bay #2 Nov 28 09:45:49 OA: Server Power Reduction - Activated Nov 28 09:45:50 OA: PS Subsystem N + N Redundancy - FAILED. Allocated Power: 640W DC, Present Power: 70W AC. Nov 28 09:45:50 OA: Enclosure Status changed from OK to Failed. (Power Subsystem) Nov 28 09:46:14 OA: PS Status Changed: Bay #4 From: unknown To: failed Nov 28 09:46:14 OA: PS Status Changed: Bay #5 From: unknown To: failed Oct 15 07:59:39 Kernel: Network link is down Oct 15 07:59:53 OA: Time zone changed to GMT+1 Oct 15 07:59:55 OA: Blade in bay #2 status changed to Unknown Oct 15 07:59:56 OA: Device 2 power delayed during device discovery. Oct 15 07:59:56 OA: LCD Status is: OK. Oct 15 07:59:57 OA: Blade in bay #2 status changed to OK Oct 15 07:59:59 Enclosure-Link: Service started Oct 15 08:00:05 Enclosure-Link: Initial topology scan completed successfully Oct 15 08:00:06 OA: Blade in bay #2 status changed from OK to Degraded Oct 15 08:00:06 OA: Partner device 2 was denied power because the corresponding device is missing. Oct 15 08:00:06 OA: HTTP server is up Oct 15 08:00:10 OA: Onboard Administrator booted successfully Oct 15 08:00:16 OA: PS Status Changed: Bay #1 From: unknown To: failed Oct 15 08:00:16 OA: PS Status Changed: Bay #4 From: unknown To: failed Oct 15 08:00:16 OA: Enclosure Status changed from OK to Degraded. (Power Subsystem) Oct 15 08:00:47 OA: VLAN is disabled Oct 15 08:01:45 OA: Internal health status of interconnect in bay 2 changed to OK Oct 15 08:05:30 OA: PS Subsystem N + N Redundancy - FAILED. Allocated Power: 540W DC, Present Power: 118W AC. Oct 15 08:37:14 Kernel: Network link is down Oct 15 08:37:28 OA: Time zone changed to GMT+1 Oct 15 08:37:30 OA: Blade in bay #2 status changed to Unknown Oct 15 08:37:30 OA: Device 2 power delayed during device discovery. Oct 15 08:37:31 OA: LCD Status is: OK. Oct 15 08:37:32 OA: Blade in bay #2 status changed to OK Oct 15 08:37:34 Enclosure-Link: Service started Oct 15 08:37:40 OA: HTTP server is up Oct 15 08:37:40 Enclosure-Link: Initial topology scan completed successfully Oct 15 08:37:41 OA: Blade in bay #2 status changed from OK to Degraded Oct 15 08:37:41 OA: Partner device 2 was denied power because the corresponding device is missing. Oct 15 08:37:44 OA: Onboard Administrator booted successfully Oct 15 08:37:51 OA: PS Status Changed: Bay #1 From: unknown To: failed Oct 15 08:37:51 OA: PS Status Changed: Bay #4 From: unknown To: failed Oct 15 08:37:51 OA: Enclosure Status changed from OK to Degraded. (Power Subsystem) Oct 15 08:38:24 OA: VLAN is disabled Oct 15 08:39:19 OA: Internal health status of interconnect in bay 2 changed to OK Oct 15 08:41:42 OA: Authentication failure for user admin on the OA serial console. Oct 15 08:50:52 Kernel: Network link is down Oct 15 08:51:06 OA: Time zone changed to GMT+1 Oct 15 08:51:08 OA: Blade in bay #2 status changed to Unknown Oct 15 08:51:08 OA: Device 2 power delayed during device discovery. Oct 15 08:51:09 OA: LCD Status is: OK. Oct 15 08:51:10 OA: Blade in bay #2 status changed to OK Oct 15 08:51:12 Enclosure-Link: Service started Oct 15 08:51:18 Enclosure-Link: Initial topology scan completed successfully Oct 15 08:51:18 OA: Blade in bay #2 status changed from OK to Degraded Oct 15 08:51:18 OA: Partner device 2 was denied power because the corresponding device is missing. Oct 15 08:51:21 OA: HTTP server is up Oct 15 08:51:24 OA: Onboard Administrator booted successfully Oct 15 08:51:29 OA: PS Status Changed: Bay #1 From: unknown To: failed Oct 15 08:51:29 OA: PS Status Changed: Bay #4 From: unknown To: failed Oct 15 08:51:29 OA: Enclosure Status changed from OK to Degraded. (Power Subsystem) Oct 15 08:52:01 OA: VLAN is disabled Oct 15 09:53:06 OA: Password for `Administrator' changed by system Oct 15 08:53:29 Kernel: Network link is down Oct 15 08:53:44 OA: Time zone changed to GMT+1 Oct 15 08:53:45 OA: Blade in bay #2 status changed to Unknown Oct 15 08:53:46 OA: Device 2 power delayed during device discovery. Oct 15 08:53:47 OA: LCD Status is: OK. Oct 15 08:53:48 OA: Blade in bay #2 status changed to OK Oct 15 08:53:50 Enclosure-Link: Service started Oct 15 08:53:56 OA: Blade in bay #2 status changed from OK to Degraded Oct 15 08:53:56 OA: Partner device 2 was denied power because the corresponding device is missing. Oct 15 08:53:57 Enclosure-Link: Initial topology scan completed successfully Oct 15 08:53:57 OA: HTTP server is up Oct 15 08:54:00 OA: Onboard Administrator booted successfully Oct 15 08:54:07 OA: PS Status Changed: Bay #1 From: unknown To: failed Oct 15 08:54:07 OA: PS Status Changed: Bay #4 From: unknown To: failed Oct 15 08:54:07 OA: Enclosure Status changed from OK to Degraded. (Power Subsystem) Oct 15 08:54:16 OA: Authentication failure for user root on the OA serial console. Oct 15 08:54:26 OA: Authentication failure for user administrator on the OA serial console. Oct 15 08:54:37 OA: VLAN is disabled Oct 15 08:54:40 OA: Authentication failure for user admin on the OA serial console. Oct 15 09:01:30 OA: Administrator logged into the Onboard Administrator on the OA serial console. Oct 15 09:03:20 Enclosure-Link: Found new Topology: New enclosure connected (1 total) Oct 15 09:14:52 Enclosure-Link: Failed to get local address. Will keep retrying Oct 15 09:15:31 Enclosure-Link: Failed to get local address. Will keep retrying Oct 15 09:15:47 OA: Static TCP/IP settings were modified by user Administrator. Oct 15 09:15:52 Kernel: Network link is down Oct 15 09:16:12 Enclosure-Link: Failed to get local address. Will keep retrying Oct 15 09:16:52 Enclosure-Link: Failed to get local address. Will keep retrying >SHOW NETWORK Enclosure Network Settings: - - - - - IPv6 Information - - - - - IPv6: Disabled DHCPv6: Disabled Router Advertisement: Disabled Onboard Administrator Network Settings: - - - - - IPv4 Information - - - - - DHCP: Disabled IPv4 Address: 192.168.16.16 Netmask: 255.255.255.0 Gateway Address: 0.0.0.0 - - - - - IPv6 Information - - - - - Static Address: Not Set Static IPv6 DNS 1: Not Set Static IPv6 DNS 2: Not Set - - - - - General Information - - - - - Active DNS Addresses: Primary: Not Set Secondary: Not Set Tertiary: Not Set MAC Address: 00:1F:29:E7:24:0D Network Link Settings: Link Auto-negotiation Onboard Administrator Protocol Status: Web (HTTP/HTTPS): Enabled SNMP: Disabled SecureSH: Enabled FIPS Mode: Off Trusted Hosts: Disabled HPSIM Trust Mode: Disabled Telnet: Enabled AlertMail: Disabled Mailbox: Not Set SMTP Server: Not Set Sender Domain: Not Set XML Reply: Enabled NTP: Enabled Primary NTP server: 192.36.144.22 Secondary NTP server: 192.36.143.151 Server Poll-Interval: 720 seconds Last Update: Update in progress Link Loss Failover: Not Supported Link Loss Interval: Not Supported Enclosure IP Mode: Not Supported GUI Login Detail: Disabled Active Health System: Enabled VLAN: Disabled >SHOW POWER Power Mode: Redundant Dynamic Power: Enabled Set Power Limit: Not Set Power Capacity: 1200 Watts DC Power Available: 660 Watts DC Power Allocated: 540 Watts DC Present Power: 181 Watts AC Power Limit: 1459 Watts AC >SHOW RACK NAME Rack Name: ByggBlade >SHOW RACK INFO Rack Information: Location hardware not found (No hardware support) >SHOW SNMP SNMP Configuration: Status: Disabled System Name: CZC8383004 System Location: System Contact: Read Community Name: public Write Community Name: No trap receivers specified. >SHOW SSHFINGERPRINT 1024 sha1:59:89:d2:4f:d4:c1:c5:63:22:c3:9f:44:e7:ec:b5:b3:ae:e3:76:ea /etc/ssh/id_dsa.pub (DSA) >SHOW SSHKEY There is no SSH key installed. >SHOW HPSIM INFO HPSIM Trust Mode: Disabled Trusted Server Certificates No certificates were found. >SHOW INTERCONNECT INFO ALL 1. Ethernet Product Name: GbE2c Ethernet Blade Switch Width: Single URL to Management interface: http://10.0.209.68 In-Band IPv4 Address: 10.0.209.68 User Assigned Name: Part Number: 410917-B21 Spare Part Number: 414037-001 Serial Number: MY383221E0 Temperature Sensor: Present JS2 Connector: Absent Internal Ethernet Interface to OA: Present Internal Ethernet Route to OA: Enabled Internal Serial Interface to OA: Absent Internal Serial Route to OA: Disabled External Serial Port Interface: Present External Ethernet Interface: Present Manufacturer: HP 2. Fibre Channel Product Name: Brocade 4/12 SAN Switch for HP c-Class BladeSystem Width: Single URL to Management interface: http://10.0.209.41 In-Band IPv4 Address: 10.0.209.41 User Assigned Name: BYGGSANSW Part Number: AE370A Spare Part Number: 411120-001 Serial Number: CN8820606G Temperature Sensor: Present JS2 Connector: Absent Internal Ethernet Interface to OA: Present Internal Ethernet Route to OA: Enabled Internal Serial Interface to OA: Present Internal Serial Route to OA: Enabled Serial Port Baud Rate: 9600 External Serial Port Interface: Absent External Ethernet Interface: Absent Manufacturer: BROCADE 3. <absent> 4. <absent> >SHOW INTERCONNECT LIST Bay Interconnect Type Manufacturer Power Health UID Management IP --- ----------------- -------------------- ------- --------- --- --------------- 1 Ethernet HP On OK Off 10.0.209.68 2 Fibre Channel BROCADE On OK Off 10.0.209.41 3 [Absent] 4 [Absent] Totals: 2 interconnect modules installed, 2 powered on. >SHOW INTERCONNECT SESSION Interconnect Bay User ------------------ -------------- No Interconnect remote console sessions were detected. >SHOW INTERCONNECT STATUS ALL Interconnect Module #1 Status: Status: OK Thermal: OK CPU Fault: OK Health LED: OK UID: Off Powered: On Diagnostic Status: Internal Data OK Management Processor OK Thermal Warning OK Thermal Danger OK Power OK Device Failure OK Device Degraded OK Interconnect Module #2 Status: Status: OK Thermal: OK CPU Fault: OK Health LED: OK UID: Off Powered: On Diagnostic Status: Internal Data OK Management Processor OK Thermal Warning OK Thermal Danger OK Power OK Device Failure OK Device Degraded OK Interconnect Module #3 Status: Interconnect Module Type: No Interconnect Module Installed Interconnect Module #4 Status: Interconnect Module Type: No Interconnect Module Installed >SHOW INTERCONNECT PORT MAP ALL 1: GbE2c Ethernet Blade Switch Type: Ethernet Width: Single Status: No Connection 2: Brocade 4/12 SAN Switch for HP c-Class BladeSystem Type: Fibre Width: Single Status: No Connection 3. <absent> 4. <absent> >SHOW INTERCONNECT POWERDELAY ALL Current PowerDelay Status: Not in Progress Bay Device PowerDelay State Delay (seconds) --- -------------------------------- ---------------- --------------- 1 GbE2c Ethernet Blade Switch Disabled 0 2 Brocade 4/12 SAN Switch for HP c Disabled 0 3 Absent Disabled 0 4 Absent Disabled 0 >SHOW SERVER LIST Bay iLO Name iLO IP Address Status Power UID Partner --- ----------------------------- --------------- -------- ------- --- ------- 1 [Absent] 2 Storage Blade N/A Degraded Off Off 3 [Absent] 4 [Absent] 5 [Absent] 6 [Absent] 7 [Absent] 8 [Absent] Totals: 1 server blades installed, 0 powered on. >SHOW SERVER NAMES Bay Server Name Serial Number Status Power UID Partner --- ----------------------------- --------------- -------- ------- --- ------- 1 [Absent] 2 Storage Blade SGI8360058 Degraded Off Off 3 [Absent] 4 [Absent] 5 [Absent] 6 [Absent] 7 [Absent] 8 [Absent] Totals: 1 server blades installed, 0 powered on. >SHOW FRU Enclosure Model: BladeSystem c3000 Enclosure Manufacturer: HP Serial Number: CZC8383004 Part Number: 437502-B21 Enclosure Midplane Manufacturer: HP Spare Part Number: 441829-001 Onboard Administrator 1 Model: BladeSystem c3000 Onboard Administrator Manufacturer: HP Serial Number: P3059%%9VW909F Part Number: 448589-B21 Spare Part Number: 441832-001 Firmware Version: 3.71 HwVersion: %% Blade 2 Model: HP StorageWorks SB40c Manufacturer: HP Serial Number: SGI8360058 Part Number: 411243-B21 Spare Part Number: 430798-001 Interconnect 1 Model: GbE2c Ethernet Blade Switch Manufacturer: HP Serial Number: MY383221E0 Part Number: 410917-B21 Spare Part Number: 414037-001 Interconnect 2 Model: Brocade 4/12 SAN Switch for HP c-Class BladeSystem Manufacturer: BROCADE Serial Number: CN8820606G Part Number: AE370A Spare Part Number: 411120-001 Fan 1 Model: Active Cool 200 Fan Part Number: 412140-B21 Spare Part Number: 413996-001 Fan 2 Model: Active Cool 200 Fan Part Number: 412140-B21 Spare Part Number: 413996-001 Fan 3 Model: Active Cool 200 Fan Part Number: 412140-B21 Spare Part Number: 413996-001 Fan 4 Model: Active Cool 200 Fan Part Number: 412140-B21 Spare Part Number: 413996-001 Fan 5 Model: Active Cool 200 Fan Part Number: 412140-B21 Spare Part Number: 413996-001 Fan 6 Model: Active Cool 200 Fan Part Number: 412140-B21 Spare Part Number: 413996-001 Power Supply 1 Model: HP PROLIANT SERVER PS Serial Number: 531290A4DW650P Part Number: 437572-B21 Spare Part Number: 441830-001 Power Supply 2 Model: HP PROLIANT SERVER PS Serial Number: 531290A4DW96UL Part Number: 437572-B21 Spare Part Number: 441830-001 Power Supply 4 Model: HP PROLIANT SERVER PS Serial Number: 531290A4DWJ1NR Part Number: 437572-B21 Spare Part Number: 441830-001 Power Supply 5 Model: HP PROLIANT SERVER PS Serial Number: 531290A4DW96UN Part Number: 437572-B21 Spare Part Number: 441830-001 Insight Display Model: BladeSystem c3000 Insight Display Manufacturer: HP Spare Part Number: 441831-001 Firmware Version: 2.2.2 >SHOW SERVER INFO ALL Server Blade #1 Information: Server Blade Type: No Server Blade Installed Server Blade #2 Information: Type: Storage Blade Manufacturer: HP Product Name: HP StorageWorks SB40c Part Number: 411243-B21 System Board Spare Part Number: 430798-001 Serial Number: SGI8360058 ROM Version: 1.20 Server Blade #3 Information: Server Blade Type: No Server Blade Installed Server Blade #4 Information: Server Blade Type: No Server Blade Installed Server Blade #5 Information: Server Blade Type: No Server Blade Installed Server Blade #6 Information: Server Blade Type: No Server Blade Installed Server Blade #7 Information: Server Blade Type: No Server Blade Installed Server Blade #8 Information: Server Blade Type: No Server Blade Installed >SHOW SERVER PORT MAP ALL Mezz Mezz Mezz Device Port Interconnect Interconnect Slot Device Port Status Bay Bay Port Device ID ---- ------ ------ ---------- ------------ ------------ ---------------- ------------------------------- Blade 001 ------------------------------- <absent> ------------------------------- Blade 002 ------------------------------- No Port Mapping information available for blade 2 ------------------------------- Blade 003 ------------------------------- <absent> ------------------------------- Blade 004 ------------------------------- <absent> ------------------------------- Blade 005 ------------------------------- <absent> ------------------------------- Blade 006 ------------------------------- <absent> ------------------------------- Blade 007 ------------------------------- <absent> ------------------------------- Blade 008 ------------------------------- <absent> >SHOW SERVER STATUS ALL Blade #1 Status: Power: No Server Blade Installed Blade #2 Status: Power: Off Current Wattage used: 0 Health: Degraded Unit Identification LED: Off Virtual Fan: 0% Diagnostic Status: Internal Data OK Management Processor OK Missing Device Failed Blade #3 Status: Power: No Server Blade Installed Blade #4 Status: Power: No Server Blade Installed Blade #5 Status: Power: No Server Blade Installed Blade #6 Status: Power: No Server Blade Installed Blade #7 Status: Power: No Server Blade Installed Blade #8 Status: Power: No Server Blade Installed >SHOW SERVER TEMP ALL Device Bay #1 Temperature Information No Server Blade Installed Device Bay #2 Temperature Information Blade Power is Off. Cannot retrieve data. Device Bay #3 Temperature Information No Server Blade Installed Device Bay #4 Temperature Information No Server Blade Installed Device Bay #5 Temperature Information No Server Blade Installed Device Bay #6 Temperature Information No Server Blade Installed Device Bay #7 Temperature Information No Server Blade Installed Device Bay #8 Temperature Information No Server Blade Installed >SHOW SERVER DVD ALL DVD Drive: Absent Server DVD connections: Bay Connected Device or image URL --- --------- ------------------------------------- 1 - [Bay empty] 2 - [Non-server blade] 3 - [Bay empty] 4 - [Bay empty] 5 - [Bay empty] 6 - [Bay empty] 7 - [Bay empty] 8 - [Bay empty] >SHOW SERVER POWERDELAY ALL Current PowerDelay Status: Not in Progress Bay Device PowerDelay State Delay (seconds) --- -------------------------------- ---------------- --------------- 1 Absent Disabled 0 1A Absent Disabled 0 1B Absent Disabled 0 2 HP StorageWorks SB40c Disabled 0 2A Absent Disabled 0 2B Absent Disabled 0 3 Absent Disabled 0 3A Absent Disabled 0 3B Absent Disabled 0 4 Absent Disabled 0 4A Absent Disabled 0 4B Absent Disabled 0 5 Absent Disabled 0 5A Absent Disabled 0 5B Absent Disabled 0 6 Absent Disabled 0 6A Absent Disabled 0 6B Absent Disabled 0 7 Absent Disabled 0 7A Absent Disabled 0 7B Absent Disabled 0 8 Absent Disabled 0 8A Absent Disabled 0 8B Absent Disabled 0 >SHOW SERVER BOOT ALL Server Blade #1 Boot Information: The blade is not present. Server Blade #2 Boot Information: One time boot from: None IPL Devices (Boot Order): Server Blade #3 Boot Information: The blade is not present. Server Blade #4 Boot Information: The blade is not present. Server Blade #5 Boot Information: The blade is not present. Server Blade #6 Boot Information: The blade is not present. Server Blade #7 Boot Information: The blade is not present. Server Blade #8 Boot Information: The blade is not present. >SHOW SYSLOG SERVER ALL Retrieving Server syslog(s) ... Server 1 Syslog: The blade is not present. Server 2 Syslog: Could not determine the ip address of the management processor for blade Server 3 Syslog: The blade is not present. Server 4 Syslog: The blade is not present. Server 5 Syslog: The blade is not present. Server 6 Syslog: The blade is not present. Server 7 Syslog: The blade is not present. Server 8 Syslog: The blade is not present. >SHOW SYSLOG ILO ALL Retrieving iLO Event Log ... Server 1 iLO Event Log: The blade is not present. Server 2 iLO Event Log: Could not determine the ip address of the management processor for blade Server 3 iLO Event Log: The blade is not present. Server 4 iLO Event Log: The blade is not present. Server 5 iLO Event Log: The blade is not present. Server 6 iLO Event Log: The blade is not present. Server 7 iLO Event Log: The blade is not present. Server 8 iLO Event Log: The blade is not present. >SHOW TOPOLOGY Detecting linked enclosures . An error occurred while communicating with the other Onboard Administrator. !. Rack Topology (top-down) Rack UUID: [Unknown] Rack Name: Enclosure Name Status Local IP Address UUID -------------------------------- -------- ----- --------------- -------------- Unknown Yes >SHOW USBKEY No USB keys detected in this Onboard Administrator. Note: USB keys can only be used in the Active Onboard Administrator. >SHOW USER (current user) Local User "Administrator" Information: Full name: System Administrator Contact Info: User Rights: Admin Account Status: Enabled Server Bay Access List: 1 1A 1B 2 2A 2B 3 3A 3B 4 4A 4B 5 5A 5B 6 6A 6B 7 7A 7B 8 8A 8B Interconnect Bay Access List: 1 2 3 4 OA Access: Yes >SHOW USER LIST * denotes current user Privilege Acct. User Name Full Name Level Status ---------------------------------------- -------------------- ---------- --------- * Administrator System Administrator Admin Enabled >SHOW LDAP INFO Directory Services (LDAP) Enabled : Disabled Local Users Enabled : Enabled NT Name Mapping : Disabled Directory Server : Directory Server SSL Port : 0 Search Context #1 : Search Context #2 : Search Context #3 : Search Context #4 : Search Context #5 : Search Context #6 : >SHOW LDAP CERTIFICATE No certificates were found. >SHOW LDAP GROUP LIST No LDAP groups were detected. >SHOW CA CERTIFICATE No CA certificates are imported. >SHOW TWOFACTOR INFO Two Factor Authentication: Enabled : Disabled Certificate Revocation : Disabled Certificate Owner Field : Subject >SHOW PASSWORD SETTINGS Strong Passwords: Disabled Minimum Password Length: 3 >SHOW UPDATE Device Name Location Version NewVersion ----------------------------------------------------------------------------------- TRAY | BladeSystem c3000 Onboard Administrator | - | 2.10 | 2.10 LCD | BladeSystem c3000 Insight Display | - | 2.2.2 | 2.2.2 BLADE | HP StorageWorks SB40c | 2 | 1.20 | 2.20 FAN | Active Cool 200 Fan | 1 | 2.9.4 | 2.9.4 FAN | Active Cool 200 Fan | 2 | 2.9.4 | 2.9.4 FAN | Active Cool 200 Fan | 3 | 2.9.4 | 2.9.4 FAN | Active Cool 200 Fan | 4 | 2.9.4 | 2.9.4 FAN | Active Cool 200 Fan | 5 | 2.9.4 | 2.9.4 FAN | Active Cool 200 Fan | 6 | 2.9.4 | 2.9.4 >SHOW SYSLOG SETTINGS Remote log: Disabled Address: Port: 514 >SHOW VCMODE Virtual Connect Mode: Disabled >SHOW SESSION TIMEOUT Session Timeout: Disabled >SHOW VLAN VLAN is disabled. OA VLAN ID = 1. Default VLAN ID (untagged) = 1. VLAN VLAN NAME ---- --------- 1 Default Device Settings BAY VLAN --- ---- 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 Interconnect Settings BAY VLAN --- ---- 1 1 2 1 3 1 4 1 >SHOW URB Utility Ready Blade (URB) Reporting Settings URB Reporting: Disabled Endpoint URL: Proxy URL: SMTP Server: Email Address: Interval: Daily at hour 0 Last Attempt: HTTP Failed on Wed Dec 31 23:00:00 1969 SMTP Failed on Wed Dec 31 23:00:00 1969 >SHOW FIRMWARE SUMMARY Enclosure Firmware Summary Onboard Administrator Firmware Information Bay Model Firmware Version --- -------------------------------------------------- ---------------- 1 BladeSystem c3000 Onboard Administrator 3.71 Enclosure Component Firmware Information Device Name Location Version NewVersion ----------------------------------------------------------------------------------- TRAY | BladeSystem c3000 Onboard Administrator | - | 2.10 | 2.10 LCD | BladeSystem c3000 Insight Display | - | 2.2.2 | 2.2.2 BLADE | HP StorageWorks SB40c | 2 | 1.20 | 2.20 FAN | Active Cool 200 Fan | 1 | 2.9.4 | 2.9.4 FAN | Active Cool 200 Fan | 2 | 2.9.4 | 2.9.4 FAN | Active Cool 200 Fan | 3 | 2.9.4 | 2.9.4 FAN | Active Cool 200 Fan | 4 | 2.9.4 | 2.9.4 FAN | Active Cool 200 Fan | 5 | 2.9.4 | 2.9.4 FAN | Active Cool 200 Fan | 6 | 2.9.4 | 2.9.4 Device Firmware Information Interconnect Firmware Information Bay Device Model Firmware Version --- --------------------------------------------------- ---------------- 1 GbE2c Ethernet Blade Switch [Not Available] 2 Brocade 4/12 SAN Switch for HP c-Class BladeSystem [Not Available] >SHOW FIRMWARE SUMMARY CSV Bay Number, Device Name, Discovered, Firmware Component, Current Version, Firmware ISO Version >SHOW FIRMWARE MANAGEMENT Enclosure Firmware Settings Enclosure: CZC8383004 Firmware Management: Disabled - Force Downgrade: Disabled - Firmware ISO URL: Not Set - Firmware Power Policy: OFF - Firmware Policy: Manual Only - Firmware Date: Not Set - Bays to Include Server Bays: None Firmware ISO Information: - ISO URL Status: N/A >SHOW FIRMWARE MANAGEMENT LOG May 29 08:40:32 Enclosure Firmware Management started. Jun 18 13:22:43 Enclosure Firmware Management started. Sep 24 11:01:36 Enclosure Firmware Management started. Dec 19 13:54:43 Enclosure Firmware Management started. Mar 10 13:43:09 Enclosure Firmware Management started. Apr 15 22:09:28 Enclosure Firmware Management started. Nov 28 08:50:29 Enclosure Firmware Management terminated. Nov 28 08:51:32 Enclosure Firmware Management started. Oct 15 08:00:01 Enclosure Firmware Management started. Oct 15 08:37:36 Enclosure Firmware Management started. Oct 15 08:51:13 Enclosure Firmware Management started. Oct 15 08:53:52 Enclosure Firmware Management started. >SHOW FIRMWARE LOG SERVER ALL There are no firmware logs to display. >SHOW SERVER FIRMWARE ALL Device Firmware Information >SHOW REMOTE_SUPPORT Status : Disabled Connection type : None IRS Hostname : IRS Port : 0 Last successful registration : 0000-00-00T00:00:00 Last successful unregistration : 0000-00-00T00:00:00 Last successful Data Collection : 0000-00-00T00:00:00 Last successful Service Event : 0000-00-00T00:00:00 Failed Data Collection attempts : 0 Failed Service Event attempts : 0 Maintenance Mode : Disabled >SHOW REMOTE_SUPPORT EVENT (No Remote Support Service Events) >SHOW DEVICE SERIAL_NUMBER BLADE ALL Blade #1 Information: The specified bay is empty. Blade #2 Information: Serial Number: SGI8360058 Blade #3 Information: The specified bay is empty. Blade #4 Information: The specified bay is empty. Blade #5 Information: The specified bay is empty. Blade #6 Information: The specified bay is empty. Blade #7 Information: The specified bay is empty. Blade #8 Information: The specified bay is empty. >SHOW SOLUTIONSID 0000000000000000 >SHOW LOGIN_BANNER Login Banner: Status : Disabled Login Banner Text : (* empty *) OA-BYGGBLADE>
[edit] iDRAC 7 configuration of esxi-f1 (drac-f1.cnap.hv.se)
- username is root password is "MoaHaHaHaa"#¤"#¤" 6 %#&#¤"
- iDRAC7 now supports updating server components using Racadm and Web GUI
- Dell Update Package (DUP) Updating Dell PowerEdge servers via bootable media / ISO
- Dell Repository Manager ,v2.0
- [ http://www.dell.com/support/home/us/en/04/Drivers/DriversDetails?driverId=9RX9M Dell Repository Manager ,v2.2] allows you to create customized bundles and repositories
- OpenManage VIB for ESXi ???
Power Supply.Slot.1 00.0C.6F Integrated Dell Remote Access Controller 2.41.40.40 Broadcom Gigabit Ethernet BCM5720 - 18:66:DA:86:B2:60 20.2.17 Broadcom Gigabit Ethernet BCM5720 - 18:66:DA:86:B2:61 20.2.17 Broadcom Gigabit Ethernet BCM5720 - 18:66:DA:86:B2:62 20.2.17 Broadcom Gigabit Ethernet BCM5720 - 18:66:DA:86:B2:63 20.2.17 BIOS 2.3.4 PERC H330 Mini 25.5.0.0019 Disk 0 in Backplane 1 of Integrated RAID Controller 1 DS03 BP13G+ 0:1 2.23 Lifecycle Controller 2.41.40.40 Dell 32 Bit uEFI Diagnostics, version 4239, 4239A33, 4239.41 4239A33 Dell OS Driver Pack, 16.10.10, A00 16.10.10 OS COLLECTOR 2.1, A00 2.1 System CPLD 1.0.3 PERC H330 Mini (Embedded) Integrated RAID Controller 1 25.5.0.0019 Information Not Available